background image

+ - A B

ODT

Sensor

Remote

Gh
Rf
Cf
Gs

Y

W

HV

AC E

QUIP
.

MODEL A77 

CONTROL

DH

DH

R/+

C/-

B

A

90-2490

90-2553

6A. WIRING AND SET-UP – MODEL A77 CONTROL

The Model A77 will measure the relative humidity and turn the dehumidifier on and off to control the humidity level to the desired setting. The 
humidity setting can be adjusted from the control, while the display allows easy access and monitoring of the humidity level in the space. It is 
recommended that the Model A77 be mounted at/near canopy height. Shield the Model A77 from direct exposure to HPS or LPS lighting.

NOTE:

 Use 18-22 AWG wire for control wiring.

Humidity can be controlled using the internal dehumidifier control, a Model A77 control, or a different external control like a thermostat.

Installing an external control eliminates the need to run the dehumidifier blower for sampling, as the control is constantly measuring the humidity 
close to the canopy. When the humidity level rises above the setting, the dehumidifier is turned on.

MODEL A77 REMOTE CONTROL WIRING

TO INSTALL AND USE THE MODEL A77 CONTROL,  

COMPLETE ALL STEPS:

1. 

Unplug the dehumidifier or turn off power to the circuit at the 
breaker or fuse.

2. 

Run thermostat cable (use 18-22 AWG wire) from the Model A77 to 
the control of the dehumidifier.

3. 

Trim about 1/4" of insulation from the end of the wires on each 
end. Insert the wire into the terminals as shown in the 

MODEL A77 

REMOTE CONTROL WIRING

 diagram below.

4. 

Restore dehumidifier power.

TO SET THE DEHUMIDIFIER TO USE THE MODEL A77 CONTROL,  

COMPLETE ALL STEPS:

1. 

With power to the dehumidifier, use the ON/OFF button to set the 
dehumidifier to the OFF position.

 

 NOTE:

 If the display backlight is not on, the first button press (any 

button) will only turn the backlight on. Press the button a second 
time to achieve the desired function.

2. 

Hold the MODE button on the on-board control for 3 seconds to 
enter the 

Installer Set-up Menu

.

3. 

The display should now read 

REMOTE

 on the left and 

DISABLED

 

on the right. Use the UP or DOWN arrow buttons to set this to 

ENABLED

90-1854

4. 

Once the display reads 

REMOTE ENABLED

, press the MODE button 

to cycle through the other settings until the display blinks 

DONE

 

for 3 seconds.

5. 

Use the ON/OFF button to turn the dehumidifier ON. The display 
on your unit should read 

REMOTE

.

6. 

Locate the Model A77 that you just set up. On the Model A77, press 
the ON button and use the arrow buttons to set your preferred 
%RH setpoint. When setting up in 

REMOTE

 mode for the first 

time, your dehumidifier will wait 3 minutes before starting to 
dehumidify, regardless of ambient conditions.

A710V1

L6-30P

A710V3

L7-30P

3