OVERVIEW 

This application note describes how to use an AND ZONEC2 to operate as a master clock to provide 
atomic time synchronization to legacy (analog) slave clocks. The ZONEC2 will interface with a network 
of slave clocks to send sync pulses at the appropriate times to keep the clock time synchronized.  
Analog clocks that implement the IBM/Simplex synchronous wired time correction mode are 
supported, such as: 

IBM 77 Series  

 

 

Simplex 77 Series, 93-9, 91-9, 941-9, 943-9   

American A4015D10    

ATS CC2000 Series 

 

Cincinnati D10 

 

 

Dukane 24SS  

 

Edwards 2400 Series 

Lathem Type SS   

 

Stromberg 3000 

 

REQUIRED EQUIPMENT 

 

AND Zone Controller 2 (ZONEC2) 

 

“Form A” Normally Open relay rated for 120VAC/30A with 12VDC coil

 (e.g., TE Connectivity 

T9AP1D52-12). Consult with a qualified electrical contractor if selecting an alternate relay.  

CONFIGURING THE AND DEVICE  

The ZONEC2 must be running firmware version 1.5.0001 or 
later. You can configure the device to send sync pulses via 
its on-board device settings, or via a configuration file.   

On-board Settings: 

Access the web page interface for the device, and select 

Device Settings 

 Peripherals

.  At the bottom of the page, 

find the 

Analog Clock Control Settings

 section, and set the 

Use GPIO 0 to control analog clocks

 

parameter to “Yes” as shown

 to the right.  Click the 

Save Peripherals Changes

 button. Reboot the 

device. 

Configuration File Settings: 

If using a configuration file, add this line before the closing line of the file: 

 

  <SlaveClock gpio_correction="01" /> 

 

Save the configuration file, and reboot the device to update the settings. The device will reboot a 
second time automatically when the new settings apply.

 

 