AND UA-621 Instruction Manual Download Page 5

 

4

 

Symbols 

 

Symbols 

Function / Meaning Recommended 

Action 

 

Standby and Turn the device on. 

 

 

Battery installation guide 

 

 

Direct current 

 

 

Type BF: Device, cuff and tubing are 

designed to provide special protection 

against electrical shocks. 

 

 

The indicator that appears while 

measurement is in progress. It blinks 

when the pulse is detected. 

Measurement is in progress. 

Remain as still as possible. 

 

I

rregular 

H

eart

b

eat indicator. (I.H.B.) 

The indicator that appears when an 

irregular heartbeat or any excessive 

body movement is detected during 

the measurement. 

 

 

Previous measurements stored in 

MEMORY. 

 

 

Full Battery

 

The battery power indicator during 

measurement.  

 

 

Low Battery

 

The battery is low when it blinks. 

Replace all batteries with new 

ones, when the indicator blinks.

Unstable blood pressure due to 

movement during the measurement. 

Try the measurement again. 

Remain very still during the 

measurement. 

The systolic and diastolic values are 

within 10 mmHg of each other. 

 

The pressure value did not increase 

during inflation. 

 

The cuff is not fastened correctly. 

 

PUL. DISPLAY ERROR 

The pulse is not detected correctly. 

Fasten the cuff correctly, and 

try the measurement again. 

SYS. 

Systolic blood pressure in mmHg 

 

DIA. 

Diastolic blood pressure in mmHg 

 

PUL./min. 

Pulse per minute 

 

 

EC directive medical device label 

 

 

EU-representative 

 

 

Manufacturer 

 

 

Date of manufacture 

 

 

Class II device 

 

 

WEEE label 

 

Summary of Contents for UA-621

Page 1: ...Digital Blood Pressure Monitor Model UA 621 Instruction Manual 1WMPD4001898E ...

Page 2: ...aring Data 11 What Is An Irregular Heartbeat 12 Pressure Bar Indicator 12 WHO Classification Indicator 12 About Blood Pressure 13 What Is Blood Pressure 13 What Is Hypertension And How Is It Controlled 13 Why Measure Blood Pressure At Home 13 WHO Blood Pressure Classification 13 Blood Pressure Variations 13 Troubleshooting 14 Maintenance 15 Technical Data 15 Dear Customers Congratulations on purch...

Page 3: ...llular telephones X ray or other devices with strong electrical fields Used equipment parts and batteries are not treated as ordinary household waste and must be disposed of according to the applicable local regulations When the AC adapter is used make sure that the AC adapter can be readily removed from the electrical outlet when necessary When reusing the device confirm that the device is clean ...

Page 4: ...h pressure oxygen chamber or an oxygen tent It may cause a fire or explosion Parts Identification Part of Display Pressure Bar Indicator and WHO Classification Indicator MEMORY Battery Indicator I H B Indicator Irregular heartbeat indicator Heart Mark Diastolic Pressure Pulse Rate Systolic Pressure 1 5V Batteries R6P LR6 or AA Battery Compartment Battery Cover Display START button Air Socket Air C...

Page 5: ...RY Full Battery The battery power indicator during measurement Low Battery The battery is low when it blinks Replace all batteries with new ones when the indicator blinks Unstable blood pressure due to movement during the measurement Try the measurement again Remain very still during the measurement The systolic and diastolic values are within 10 mmHg of each other The pressure value did not incre...

Page 6: ...n memory automatically 2 Recalling Data Refer to page 11 When nothing is displayed press and hold the START button to display the data number The data number of the most recent measurement and the data are displayed Stored data are automatically displayed in order from the last data 3 Clearing Data Refer to page 11 Remove the batteries to clear all data Re install them again 4 Measurement With The...

Page 7: ...e ambient temperature and may be shorter at low temperatures Use the specified batteries only The batteries provided with the device are for testing monitor performance and may have a limited life Remove the batteries if the device is not to be used for a long time The batteries may leak and cause a malfunction The stored data are cleared when the batteries are removed When the AC adapter is used ...

Page 8: ...2 cm Adult cuff CUF D A Arm size The circumference at the biceps Note Model UA 621 is not designed for using a small adult cuff Symbols printed on the cuff Symbols Function Meaning Recommended Action Artery position mark Set the mark on the artery of the upper arm or in line with the ring finger on the inside of the arm Index REF Catalog number Proper fit range for the adult cuff It s printed on t...

Page 9: ...measurement Place the center of the cuff at the same height as your heart Remain still and keep quiet during measurement Do not measure immediately after physical exercise or a bath Rest before taking the measurement Try to measure your blood pressure at the same time every day Measurement During measurement it is normal for the cuff to feel very tight Do not be alarmed After Measurement After mea...

Page 10: ...op inflation at any time press the START button again 3 When inflation is complete deflation starts automatically and the heart mark blinks indicating that the measurement is in progress Once the pulse is detected the mark blinks with each pulse beat Note If an appropriate pressure is not obtained the device starts to inflate again automatically 4 When the measurement is complete the systolic and ...

Page 11: ...otional stress the measurement will reflect this stress as a higher or lower than normal blood pressure reading and the pulse reading will usually be faster than normal An individual s blood pressure varies constantly depending on what you are doing and what you have eaten What you drink can have a very strong and rapid effect on your blood pressure This device bases its measurements on the heartb...

Page 12: ...a 1 When nothing is displayed press and hold the START button to display the data number The data number of the most recent measurement and the data are displayed 2 The data are automatically displayed in turn 3 The display will shut off automatically after all data is displayed Note If you press the START button while recalling data the device starts measurement Clearing Data Remove the batteries...

Page 13: ...ements Note We recommend contacting your physician if you see this indicator frequently Pressure Bar Indicator The indicator monitors the progress of pressure during measurement WHO Classification Indicator Each six segments of the bar indicator correspond to the WHO blood pressure classification described on the next page The indicator displays a segment based on the current data corresponding to...

Page 14: ...duce salt and fat intake Have regular physical checkups Maintain proper weight Why Measure Blood Pressure At Home Blood pressure measured at a clinic or doctor s office may cause apprehension and can produce an elevated reading 25 to 30 mmHg higher than that measured at home Home measurement reduces the effects of outside influences on blood pressure readings supplements the doctor s readings and ...

Page 15: ...e batteries are drained completely the mark does not appear Replace all batteries with new ones The cuff is not fastened properly Fasten the cuff correctly You moved your arm or body during the measurement Make sure you remain very still and quiet during the measurement The cuff position is not correct Sit comfortably and still Raise your hand so that the cuff is at the same level as your heart Th...

Page 16: ...asurement method Oscillometric measurement Measurement range Pressure 20 280 mmHg Pulse 40 180 beats minute Measurement accuracy Pressure 3 mmHg Pulse 5 Number of measurements Approximately 200 measurements when AA manganese batteries are used with pressure value of 180 mmHg at room temperature of 23 C Power supply 4 x 1 5V batteries R6P LR6 or AA or AC adapter TB 233 Not included Classification I...

Page 17: ...233C Input 100 240V Output 6V 500mA TB 233BF Input 240V Output 6V 500mA Accessories sold separately Arm size The circumference at the biceps AC adapter Catalog Number Plug Outlet type TB 233C Type C TB 233BF Type BF Note Specifications are subject to change without prior notice EMC table information is listed on our website http www aandd jp products manual medical emc_en pdf Cuff Catalog Number C...

Page 18: ...don Business Park Abingdon Oxfordshire OX14 1DY United Kingdom Telephone 44 1235 550420 Fax 44 1235 550485 A D ENGINEERING INC 1756 Automation Parkway San Jose California 95131 U S A Telephone 1 408 263 5333 Fax 1 408 263 0119 A D AUSTRALASIA PTY LTD 32 Dew Street Thebarton South Australia 5031 AUSTRALIA Telephone 61 8 8301 8100 Fax 61 8 8352 7409 ...

Reviews: