background image

 13

6.  INSTALLING THE PRINTER PAPER   

(This chapter is applicable only to the TM-2655P.) 

With the power turned on, install the printer paper as follows: 

1.  Cut the top end of the printer paper with scissors. If the end is 

not smooth, it may cause a paper jam or damage the printer 
head. 

 

2. Press lightly on the center of the printer cover to open the 

cover. 

 

 

 

 

 

3.  Raise the lever located on the right side of the printer. Insert 

the printer paper into the paper feed slot as shown. The paper 
is fed automatically. 

 

 

 

 

 

4. Press the PAPER FEED switch to feed the paper by 10 cm. 

Confirm that the paper is fed straight. If not, re-install the paper 
because it may cause a paper jam. 

5. Lower the lever and feed the paper. The paper will be cut 

automatically. 

 

 

6.  Close the cover. Press lightly on the center of the printer cover 

to secure it in position. 

 

 

Note 

 With high-speed printing, about 700 printings can be 

performed. With three-line printing, about 600 printings. 

 

Replace the printer paper when the red end is reached. 

 

Use the specified thermal paper, which is sold separately.

 

Fig.11 Paper installation procedure 

Summary of Contents for tm-2655

Page 1: ...Automatic Blood Pressure Monitor WM PD4000206E ...

Page 2: ...oduced transmitted transcribed or translated into any language in any form by any means without the written permission of A D Company Ltd The contents of this manual and the specifications of the instrument covered by this manual are subject to change for improvement without notice ...

Page 3: ...ert you to a situation that might cause injury and or damage to your property if instructions are not followed CAUTION Important information to alert you to a situation that might cause minor injury and or damage to your property if instructions are not followed Note Important information that helps users operate the device ...

Page 4: ...cal Blood Pressure Measuring Systems This is evidenced by the mark of conformity accompanied by the reference number of a designated authority This device was designed for use by adults only Compliance with the Australian EMC Frame Work This device conforms to the following requirements EMC Emission Standard for Industrial Scientific and Medical Equipment AS NZS 2064 1997 EMC Generic Immunity stan...

Page 5: ...No device can replace regular medical checkups by a doctor A doctor should verify the blood pressure measurements before making adjustments to medication When the device gets wet because of a liquid spill If the device gets wet promptly stop using it Remove the device from the patient and secure the patient s safety Turn the power off and disconnect the power cable from the electrical outlet Affix...

Page 6: ...e If medical or operational problems are found in the device or the patient stop using the device immediately check the status of the patient and take proper action Do not use the device during MRI scanning Do not use the device on a patient using a heart lung machine High frequency interference by electrosurgery or energy discharged by a defibrillator may damage the device Follow the precautions ...

Page 7: ...ain Unit 6 2 2 Rear Panel 7 2 3 Symbols 7 3 INSTALLATION 8 4 OPERATION 9 5 SETTING THE CLOCK 11 5 1 Clock Adjustment Mode 11 5 2 A Setting Example 11 6 INSTALLING THE PRINTER PAPER 13 7 SETTING THE FUNCTIONS 14 7 1 Function Setting Mode 14 7 2 Description of the Functions 15 7 3 Printing Samples 16 8 COMMUNICATION SPECIFICATIONS 17 8 1 Channel 1 Miniature DIN 8 pin 17 8 2 Channel 2 D sub 9 pin 18 ...

Page 8: ...Cover 19 9 2 Replacing the Fuses 20 9 3 Checking the Counter 20 Displaying the counter 20 Resetting the counter 20 9 4 Error Codes 20 9 5 Maintenance 21 9 6 Cleaning 21 9 7 Options and Consumables 22 10 TROUBLESHOOTING 23 11 EXTERNAL DIMENSIONS 24 ...

Page 9: ...sure your blood pressure The TM 2655 TM 2655P is suitable for mass medical check ups at firms and sports facilities and in hospital waiting rooms when used for a pre check of the patient s health status BUILT IN PRINTER TM 2655P only The TM 2655P is equipped with a printer unit which allows measurement results to be printed out for record keeping The print format can be selected from results only ...

Page 10: ...is device carefully at all times Strong shock to the device may cause trouble during operation Note Save the packing material for later use Unpack the TM 2655 TM 2655P carefully and verify that the following items are contained Fig 1 Items contained ...

Page 11: ...ressure 3 mmHg Pulse rate 5 Measurement range Blood pressure 10 280 mmHg Pulse rate 30 200 bpm Pressurizing method Micro pump Air pressure control method Rubber valve ceramic valve Rapid air exhaust system Electromagnetic valve Safety mechanism The electromagnetic valve is released when approx 320 mmHg or greater is detected Communications functions Serial output RS232C level Environment specifica...

Page 12: ...nit Fig 2 TM 2655 TM 2655P whole view Note The printer unit is available only for the TM 2655P The human sensor area appears the same for both models but it functions only for the TM 2655P The illustration above is not to scale ...

Page 13: ... the device off Alternating current Serial number Fuse RS 232C Date of manufacture Type B Device cuff and tubing are designed to provide special protection against electrical shocks The medical device label by the EC directive The certification trade mark registered to the Australian Communications Authority by the Trademarks office SYSTOLIC SYS Systolic blood pressure in mmHg DIASTOLIC DIA Diasto...

Page 14: ...ve gases It is not exposed to direct sunlight 2 Place the TM 2655 TM 2655P on a table solid enough to support its weight 3 Adjust the height of the chair and table so that the arm insertion section is at the user s heart level Fig 4 Proper installation 4 Use the power cable provided with the device to connect between the AC INPUT connector and an electrical outlet Using the anti theft opening secu...

Page 15: ...thick jacket take it off for a better measurement Note Wearing a thick jacket may cause a faint pulse and result in a measurement error 3 Adjust the height of the chair and table Adjust the height of the chair and table so that the arm insertion section is at your heart level 4 Insert your arm into the arm insertion section Note Be sure to insert your arm to the shoulder 5 Press the START STOP swi...

Page 16: ...nt at any time press the START STOP switch The quick exhaust will reduce the pressure in the cuff and the cuff will become loose If the air is not exhausted even when the START STOP switch is pressed press the EMERGENCY STOP switch If your arm can not be removed from the cuff due to the power failure press the safety lever located on the front lower part of the device It disconnects the clutch to ...

Page 17: ...the switch is pressed the flashing unit changes from Year to Month Date Hours and Minutes 3 Press to quit the clock adjustment mode switch Press to change the flashing digit s 5 2 A Setting Example The following is the procedure to adjust the clock to 14 07 April 20 2001 1 Press the SELECT switch to make the SYSTOLIC display flash 2 Press the switch to display 01 for 2001 3 Press the SELECT switch...

Page 18: ...isplay 07 11 Press the SELECT switch to return to the measurement mode Note If no operation is performed for one minute while setting the minutes section and for five seconds while setting the others the settings performed so far will be confirmed and the device will return to the measurement mode The clock can be set up to December 31 2091 ...

Page 19: ... paper feed slot as shown The paper is fed automatically 4 Press the PAPER FEED switch to feed the paper by 10 cm Confirm that the paper is fed straight If not re install the paper because it may cause a paper jam 5 Lower the lever and feed the paper The paper will be cut automatically 6 Close the cover Press lightly on the center of the printer cover to secure it in position Note With high speed ...

Page 20: ...witch Hold down the switch and press the SELECT switch to enter the function setting mode COUNTER switch Press to select the function to set switch Press to select the function parameter 1 Hold down the switch and press the SELECT switch f01 appears in the SYSTOLIC pressure display This indicates that the monitor is now in the function setting mode 2 Press the COUNTER switch to select the function...

Page 21: ...splaying time f04 20 Displays the results for 20 seconds 1 Terminals 1 and 2 to a PC 2 Terminal 1 to a PC Terminal 2 to a card reader F05 External connection Ff05 3 Terminal 1 to a scale Terminal 2 to a PC au Automatic pressurization 160 Pressurizes the cuff up to 160 mmHg 180 Pressurizes the cuff up to 180 mmHg F06 Pressurization Ff06 200 Pressurizes the cuff up to 200 mmHg 120 1200 bps 240 2400 ...

Page 22: ...rinting 3 line printing Table printing Bit pattern printing Fig 13 Printing samples Note Bit pattern printing is available only for the TM 2655P With this format some items such as the company name can be printed For details contact your nearest dealer ...

Page 23: ...ansmission Asynchronous half duplex Baud rate 1200 2400 4800 9600 bps Can be changed in the function setting mode F07 Data bits 8 bits Parity bit None Stop bits 1 bit Code ASCII Equipment available for connection Channel 1 Scales and automatic weight and height scales manufactured by A D Channel 2 Personal computer Pin assignment Pin No Signal name Description 1 TXD Send data 2 RXD Receive data 3 ...

Page 24: ...etting mode F08 Data bits 8 bits Parity bit None Stop bits 1 bit Code ASCII Equipment available for connection Channel 1 Personal computer Channel 2 Card reader Pin assignment Pin No Signal name Direction Description 1 2 RXD In Receive data 3 TXD Out Send data 4 DTR Out Data terminal ready 5 GND Signal ground 6 DSR In Data set ready 7 RTS Out Ready to send 8 CTS In Clear to send 9 Fig 16 Pin assig...

Page 25: ... 3 Remove the front vinyl ring of the arm cuff cover from the groove Remove the rear vinyl ring of the arm cuff cover from the groove Pull out the arm cuff cover 4 Place a new arm cuff cover in the arm cuff Secure the front and rear vinyl rings of the arm cuff cover in the groove Smooth the cover cloth near the grooves 5 Replace the rear panel the armrest and the front frame in the reversed order ...

Page 26: ...is turned off Use the counter function to check the frequency of the device use or as the guideline for a periodic cleaning Displaying the counter Press the COUNTER switch The counter data appears in the SYSTOLIC and DIASTOLIC displays for about 4 seconds Note Do not keep the COUNTER switch pressed It will reset the counter data to zero Resetting the counter Hold down the COUNTER switch for 4 seco...

Page 27: ... with the regulations governing manufacturing of medical products 9 6 Cleaning CAUTION Never immerse the TM 2655 TM 2655P in water for cleaning that may damage the electronic parts inside Never use thinner or a strong detergent for cleaning that may discolor or deform the plastic case and display panel Housing case Clean the case gently using a soft cloth moistened with water and mild detergent or...

Page 28: ...shown below Order them from the nearest dealer Use the part numbers when ordering Table TM 9325 Standard stool TM 9312 Chair Gas shock suspension TM 9315A Printer paper 5 rolls AX PP147 S Arm cuff cover AX 133003442 S Power cable cord set KO 243 for 230VAC Power cable cord set KO 242 for 240VAC ...

Page 29: ... during the measurement Relax and remain still Wearing a thick jacket may cause a faint pulse and result in a measurement error Take off the jacket The device will not measure Eerr appears This device bases its measurements on the heartbeat If you have a very weak or irregular heartbeat the device may have difficulty determining your blood pressure Is the printer paper installed pe appears Refer t...

Page 30: ...24 11 EXTERNAL DIMENSIONS Fig 20 External dimensions Note The illustration above indicates the TM 2655P with the printer unit The dimensions are the same for the TM 2655 and TM 2655P ...

Reviews: