FG-27CWP Bluetooth® Communication Interface for FG-CWP
INSTRUCTION MANUAL
FG-27CWP is a wireless communication option. Attach to the FG-CWP series scale.
1.
Installation Procedure
Note: Before installing the FG-27CWP option board, remove the USB plug from the power supply.
1) Remove the protective cover from the four screws of the Load cell/CAL cover on the
rear of the display unit,
and then loosen the four screws and open the Load cell/CAL
cover.
2) Insert the FG-27CWP into the display unit and connect the connector (5 pin).
3) Tighten the Load cell/CAL cover with four screws.
2.
Attaching Certification ID label
Attach the Certification ID label included with this product
to the outer surface of the Load cell/CAL cover.
Note: Must be affixed to clarify the use of wireless devices.
3.
Connectable device
□
Smartphone / Tablet / PC with
Bluetooth
® : Refer to “6. HID Function”.
□
AD8931
: Wireless Remote Display
□
AD8541-PC
: Wireless Communication Interface for PC
(Connect to USB port of computer)
Note 1 Refer to the A&D website for details.
Note 2 Turn off DIP switch No. 1 when connecting to AD8931 or AD8541-PC.
Refer to “4. DIP Switch”, Case 3.
4.
DIP Switch
5.
Setting the scale (FG-CWP series)
Refer to the instruction manual of the scale (FG-CWP series), to set the functions.
1) Set function “
” to ” ”.
2) Set function “
” to ” ”.
3) Set function “
” to ” ”.
(In case of connection to AD8931)
4) Set function “
” to ” ”.
6.
HID function (HID Over GATT Profile)
□
By turning on DIP switch No. 1, you can connect to a Smartphone, tablet, or PC with
Bluetooth
® and use a general-
purpose text application or spreadsheet software.
□
The output data has no header (ST, WT, etc.), + sign and unit (g, kg, etc.).
□
Set the keyboard language of device to English.
□
By turning on DIP switch No.2, the output data has serial number (S/N) of scale. Refer to “4. DIP switch”, Case 2.
Pairing
□
Turn on the
Bluetooth
® function of connection device and power on the scale. Select the “A&D_HID” device and pair.
S/N
may have been added after “A&D_HID”.
□
You will not be able to connect if more than 30 seconds have passed without pairing after selecting the device.
In that case,
power off the scale and try again.
7.
Precautions for use
□
Refer to the instruction manual of the connection device for the pairing.
□
The mark lights up when the wireless communication connection is completed.
□
It will connect automatically when the paired device is nearby. When connecting to other device, turn off the unused devices
or disconnect.
□
If you can’t communicate, check that the connector is firmly connected. If it still fails, check the scale settings, pairing or
re-pairing and connected devices.
8.
Wireless communication
□
Bluetooth
® devices is
EYSHCNZXZ (TAIYO YUDEN CO.,LTD.)
/
Bluetooth
® 5.0 (Bluetooth Low Energy)
□
The effective range communication is 10 m or less in an unobstructed space. If there is an obstacle such as a wall, the
range of communication will be shorter.
□
Interference may be caused near the following devices that use the 2.4 GHz frequency band, which is the same as for
Bluetooth
®. Therefore, this device is not suited for uses that require reliability.
- Wireless LAN
-
Bluetooth
® devices such as mobile phones
- Home appliances such as microwave ovens
9.
Compliance
9-1. Compliance with FCC Rules
This device contains transmitter module FCC ID: RYYEYSHCN
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation. (FCC = Federal Communications Commission in the U.S.A.)
FCC warning
Changes or modification not expressly approved by the party responsible for compliance could void the user’s authority
to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to part
15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his / her own expense.
9-2. IC
IC RADIATION EXPOSURE STATEMENT FOR CANADA
This device complies with Industry Canada license-exempt RSS standards. Operation is subject to the following two
conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference
that may cause undesired operation of the device. This device contains transmitter module IC: 4389B-EYSHCN
Case
DIP switch
Output data
No. 1
No. 2
SELECT
SERIAL
1
Keyboard input
No S/N
(Factory Setting)
ON
OFF
Only numerical data
(No
header, no +sign and no unit
)
Example 1)
1.23
Example 2)
-
4.56
Data
2
Keyboard input
With S/N
ON
ON
Add S/N before numerical data
(Same as case 1 if the balance has no S/N setting)
Example 1)
12345678
1.23
Example 2)
901234567
-4.56
S/N Tab Data
3
Two-way
communication
OFF
OFF
Connect to AD8931 or AD8541-PC
A&D Company, Limited
3-23-14 Higashi-Ikebukuro, Toshima-ku, Tokyo 170-0013, JAPAN
Telephone: [81] (3) 5391-6132 Fax: [81] (3) 5391-1566
Certification ID Label
Load cell/CAL cover
FG-27CWP
DIP switch