FG-27CWP is a wireless communication option. Attach to the FG-CWP series scale.

   

1.

 

Installation Procedure 

Note: Before installing the FG-27CWP option board, remove the USB plug from the power supply. 

1) Remove the protective cover from the four screws of the Load cell/CAL cover on the   

rear of the display unit,

 

and then loosen the four screws and open the Load cell/CAL 

cover. 

2) Insert the FG-27CWP into the display unit and connect the connector (5 pin). 
3) Tighten the Load cell/CAL cover with four screws. 

 

2.

 

Attaching Certification ID label   

Attach the Certification ID label included with this product   

to the outer surface of the Load cell/CAL cover. 

Note: Must be affixed to clarify the use of wireless devices. 

 

 

 

3.

 

Connectable device 

  Smartphone / Tablet / PC with 

Bluetooth

®  : Refer to “6. HID Function”.   

  AD8931 

  : Wireless Remote Display   

  AD8541-PC 

  : Wireless Communication Interface for PC 

(Connect to USB port of computer) 

Note 1  Refer to the A&D website for details

https://www.aandd.co.jp/

 

Note 2  Turn off DIP switch No. 1 when connecting to AD8931 or AD8541-PC.

 

 

Refer to “4. DIP Switch”, Case 3.

 

 

4.

 

DIP Switch 

 

5.

 

Setting the scale (FG-CWP series) 

Refer to the instruction manual of the scale (FG-CWP series), to set the functions. 

1)  Set function “

” to ” ”. 

2)  Set function “

” to ” ”. 

3)  Set function “

” to ” ”.

  

(In case of connection to AD8931) 

4)  Set function “

” to ” ”.

 

 

 

6.

 

HID function (HID Over GATT Profile)

 

  By turning on DIP switch No. 1, you can connect to a Smartphone, tablet, or PC with 

Bluetooth

® and use a general-

purpose text application or spreadsheet software.   

  The output data has no header (ST, WT, etc.), + sign and unit (g, kg, etc.). 

  Set the keyboard language of device to English. 

  By turning on DIP switch No.2, the output data has serial number (S/N) of scale. Refer to “4. DIP switch”, Case 2. 

 

Pairing 

  Turn on the 

Bluetooth

® function of connection device and power on the scale. Select the “A&D_HID” device and pair.

 

S/N 

may have been added after “A&D_HID”.

 

  You will not be able to connect if more than 30 seconds have passed without pairing after selecting the device.

 

In that case, 

power off the scale and try again. 

 

7.

 

Precautions for use 

  Refer to the instruction manual of the connection device for the pairing.

 

  The   mark lights up when the wireless communication connection is completed. 

  It will connect automatically when the paired device is nearby. When connecting to other device, turn off the unused devices 

or disconnect. 

  If you can’t communicate, check that the connector is firmly connected. If it still fails, check the scale settings, pairing or 

re-pairing and connected devices. 

 

8.

 

Wireless communication 

 

Bluetooth

® devices is

 

EYSHCNZXZ (TAIYO YUDEN CO.,LTD.)

Bluetooth

® 5.0 (Bluetooth Low Energy) 

  The effective range communication is 10 m or less in an unobstructed space. If there is an obstacle such as a wall, the   

range of communication will be shorter.

 

  Interference may be caused near the following devices that use the 2.4 GHz frequency band, which is the same as for 

Bluetooth

®. Therefore, this device is not suited for uses that require reliability.   

 

 

- Wireless LAN 

Bluetooth

® devices such as mobile phones 

- Home appliances such as microwave ovens 

 

9.

 

Compliance 

  9-1. Compliance with FCC Rules 

This device contains transmitter module FCC ID: RYYEYSHCN 

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:   

(1)  this device may not cause harmful interference, and (2) this device must accept any interference received, including   

interference that may cause undesired operation. (FCC = Federal Communications Commission in the U.S.A.) 

 

FCC warning 

Changes or modification not expressly approved by the party responsible for compliance could void the user’s authority 

to operate the equipment. 

 

Note: This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to part 

15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the 

equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency 

energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio 

communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case 

the user will be required to correct the interference at his / her own expense. 

 

 

9-2. IC 

IC RADIATION EXPOSURE STATEMENT FOR CANADA 

This device complies with Industry Canada license-exempt RSS standards. Operation is subject to the following two 

conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference 

that may cause undesired operation of the device. This device contains transmitter module IC: 4389B-EYSHCN 

 

 

Case 

DIP switch 

Output data 

No. 1 

No. 2 

SELECT 

SERIAL 

Keyboard input 

No S/N 

(Factory Setting) 

ON 

OFF 

Only numerical data 

(No 

header, no +sign and no unit

Example 1) 

1.23 

Example 2) 

-

4.56

 

 

Data 

 

Keyboard input 

With S/N

 

ON 

ON 

Add S/N before numerical data 

(Same as case 1 if the balance has no S/N setting) 

Example 1) 

12345678   

1.23 

Example 2) 

901234567  

-4.56 

         

   

     

S/N    Tab  Data 

 

 

Two-way 

communication 

OFF 

OFF 

Connect to AD8931 or AD8541-PC 

 

 

A&D Company, Limited 

3-23-14 Higashi-Ikebukuro, Toshima-ku, Tokyo 170-0013, JAPAN 
Telephone: [81] (3) 5391-6132  Fax: [81] (3) 5391-1566 

Certification ID Label 

Load cell/CAL cover

 

FG-27CWP

 

DIP switch 

Summary of Contents for FG-27CWP

Page 1: ...して ください 接続機器のキーボードの設定について タブレット スマートフォンの入力モードが日本語になっていると受信不良や文字化けをしますので アルファベット入力モード に設定してからデータを受信してください 英語キーボードアプリのインストールが必要な場合もありますので タブレット スマートフォンの設定方法の詳細は A D HP を参照ください https www aandd co jp ペアリング中はキーボード切替のできない機器 iPhone などの場合 がありますので ペアリングをする前 またははかりの電 源を OFF にした状態でキーボードをアルファベット入力に切り替えてください 8 使用上の注意 ペアリングの方法 通信の方法は上記接続機器の取扱説明書を参照ください 無線接続が確立すると表示の マークが点灯します 過去にペアリングした機器が近くにあると自動的に接続するので HID 機...

Page 2: ...nication Bluetooth devices is EYSHCNZXZ TAIYO YUDEN CO LTD Bluetooth 5 0 Bluetooth Low Energy The effective range communication is 10 m or less in an unobstructed space If there is an obstacle such as a wall the range of communication will be shorter Interference may be caused near the following devices that use the 2 4 GHz frequency band which is the same as for Bluetooth Therefore this device is...

Reviews: