background image

AD-4402-20

Page 13

4.2.2.

4.2.2.

4.2.2.

4.2.2.

 

Storing Commands

Storing Commands

Storing Commands

Storing Commands

Command name

Command code

at RWw000E

Data of

RWw000C,

RWw000D

Description

Material name 1 (character no. 1 to 4)

1

Material name 2 (character no. 5 to 8)

2

Material name 3 (character no. 9 to 12)

3

Characters

Material hopper

5

Full

6

Free fall

7

Preliminary

8

Optional preliminary

9

Over

10

Under

11

Zero band

12

Full

13

Tare

14

Supplementary flow open timer

15

Supplementary flow close timer

16

Automatic free fall range

17

Initial dribble flow

18

Initial medium flow

19

Value

The command for
material code.

Select the material
code before calling
the code.
Set the code
number using
"writing command
code 33"

Recall material code

32

Material code to store

33

0 to 99

Recipe name 1 (character no. 1 to 4)

40

Recipe name 2 (character no. 5 to 8)

41

Recipe name 3 (character no. 9 to 12)

42

Characters

Material 1

44

Material  2

45

Material  3

46

Material  4

47

Material  5

48

Material  6

49

Material  7

50

Material  8

51

Material  9

52

Material  10

53

Value

The command for
recipe code.

Select the recipe
code before calling
the code.
Set the code
number using
"writing command
code 57"

Recall recipe code

56

Recipe code to store

57

0 to 99

Caution

Use ASCII code.
Put a space code (20h) in material name or recipe name, when they are not used.

Summary of Contents for CC-Link Interface AD-4402-OP-20

Page 1: ...ふ Interface WM PD4000299A ...

Page 2: ...ubject to change without notice at any time to improve the product No part of this manual may be photocopied reproduced or translated into another language without the prior written consent of the A D Company Product specifications are subject to change without any obligation on the part of the manufacture ...

Page 3: ...ess Map of the Remote Register 6 4 1 2 Address Map of the Remote Input Output 8 4 2 Communication Commands 12 4 2 1 Reading Commands 12 4 2 2 Storing Commands 13 4 3 Timing Chart 15 4 3 1 When Turning on the Indicator 15 4 3 2 Resumption from the Suspended Mode 15 4 3 3 Requesting Interface Initialization from the Master Unit 16 4 3 4 Storing Setpoints 16 4 3 5 Reading Commands 17 4 3 6 Storing Co...

Page 4: ...rcial environment If this unit is operated in a residential area it may cause some interference and under these circumstances the user would be required to take at his own expense whatever measures are necessary to eliminate the interference FCC Federal Communications Commission in the U S A 1 1 2 1 1 2 1 1 2 1 1 2 Compliance with Compliance with Compliance with Compliance with European Directive ...

Page 5: ... registers or communication commands 2 1 2 1 2 1 2 1 Precaution Precaution Precaution Precautions s s s Before any use confirm the following articles for safe operation CC link connection Conform to the specification of the CC link version 1 10 Grounding the option Ground the option to an earth ground Communication cable Use a special shielded cable made by the CC link partner vender Wiring the ca...

Page 6: ... occupied Avoid any overlapped station numbers Baud rate switch Switch No Baud rate 0 156 kbps 1 625 kbps 2 2 5 Mbps 3 5 Mbps 4 10 Mbps Status LED Name Illuminated Off Blinking RUN Normal Resetting No signal SD Transmitting RD Receiving ERR Parameter error CRC error Station trouble Normal Changing parameter Station number switch Address number switch Status LED Connector Connector F5210A 5P Baud r...

Page 7: ...Do not touch any inside parts within ten seconds after removing the power cord because you may receive an electric shock Do not forget to tighten the screws If a screw is not tightened it may cause a short circuit or an error due to noise Three option boards can be installed in the slots Initialize the RAM data in accordance with the proper procedure Refer to the AD 4402 instruction manual for oth...

Page 8: ...p of the Remote Register Address Map of the Remote Register Assumed that station No is 1 Remote Register for the AD 4402 to the Master Unit Caution Do not write any parameter to addresses Not used by the remote output RY or remote register RWw It may cause an operation error The addresses Not used by the remote input RX and remote register RWr are variable Station No Remote register Buffer Descrip...

Page 9: ... Free fall 16 bits RWw006 1E6 Over 16 bits 2 RWw007 1E7 Under 16 bits RWw008 1E8 RWw009 1E9 Full 32 bits RWw00A 1EA 3 RWw00B 1EB Zero band 16 bits RWw00C 1EC RWw00D 1ED Command data 32 bits RWw00E 1EE Command code 16 bits 4 RWw00F 1EF Not used Example of Numerical Number Hexadecimal numbers Decimal numbers 16 bits 24 bits 32 bits 10 FFF6 FFFFF6 FFFFFFF6 1 FFFF FFFFFF FFFFFFFF 0 0000 000000 0000000...

Page 10: ...005 Not used RX0006 CPU normal operation RX0007 Not used RX0008 Decimal point 20 RX0009 Decimal point 21 RX000A Decimal point 22 Three bits binary RX000B to RX000F 0E0 Not used RX0010 Zero band RX0011 Full flow RX0012 Medium flow RX0013 Dribble flow RX0014 Over RX0015 OK RX0016 Under RX0017 Stable RX0018 Batch finish RX0019 Capacity exceeded RX001A Hold RX001B Full RX001C Not used RX001D Discharge...

Page 11: ...003B Tare RX003C Center of zero RX003D Gross display RX003E Net display 2 RX003F 0E3 Hold RX0040 Material hopper 1 RX0041 Material hopper 2 RX0042 Material hopper 3 RX0043 Material hopper 4 RX0044 Material hopper 5 RX0045 Material hopper 6 RX0046 Material hopper 7 RX0047 Material hopper 8 RX0048 Material hopper 9 RX0049 Material hopper 10 RX004A Material hopper 11 RX004B Material hopper 12 RX004C ...

Page 12: ...No Flags bits and CC link Handshake of Remote Input Buffer Description RY0000 Request flag to store setpoints RY0001 Not used RY0002 Command request flag RY0003 Read Write selection flag RY0004 to RY000F 160 Not used RY0010 Zero RY0011 Zero clear RY0012 Tare RY0013 Tare clear RY0014 Hold RY0015 Net display RY0016 Gross display RY0017 Not used RY0018 Total command RY0019 Total clear Current materia...

Page 13: ...Clear total of current material code RY0038 Clear all totals of material code RY0039 Clear total of current recipe code RY003A Clear all totals of recipe code 2 RY003B to RY003F 163 Not used RY0040 RY0041 RY0042 Not used RY0043 Force batch finish RY0044 Force recipe finish RY0045 Force discharge finish RY0046 to RY004A Not used RY004B Error reset RY004C RY004D Not used RY004E Manual print RY004F 1...

Page 14: ...ic free fall range 17 Initial dribble flow 18 Initial medium flow 19 Total weight 20 Total count 21 The command for material code Select the material code before calling the code Set the code number using writing command code 33 Current material code 32 Material code to store 33 Weighing result 36 To read the last result Recipe name 1 character no 1 to 4 40 Recipe name 2 character no 5 to 8 41 Rec...

Page 15: ...l medium flow 19 Value The command for material code Select the material code before calling the code Set the code number using writing command code 33 Recall material code 32 Material code to store 33 0 to 99 Recipe name 1 character no 1 to 4 40 Recipe name 2 character no 5 to 8 41 Recipe name 3 character no 9 to 12 42 Characters Material 1 44 Material 2 45 Material 3 46 Material 4 47 Material 5 ...

Page 16: ...h material code 0 14 Set the material code at storing command No 33 before use Clear total of each recipe code 0 15 Set the recipe code at storing command No 57 before use Pause 0 22 Re start 0 23 Clear accumulation data of active material code 0 24 Clear all totals of material code 0 25 Clear total of active recipe code 0 26 Clear all totals of recipe code 0 27 Forced batch finish 0 36 Forced rec...

Page 17: ... the request flag of initialization RX0078 is active on the AD 4402 side 2 The master unit initializes the option interface and turns on the reply flag of initialization RY0078 3 AD 4402 turns off the request flag of initialization RX0078 and turn on the remote READY flag RX007B 4 Turn off the reply flag of initialization RY0078 on the master unit side 4 3 2 4 3 2 4 3 2 4 3 2 Resumption from the S...

Page 18: ...DY flag RX007B 4 3 4 4 3 4 4 3 4 4 3 4 Storing Storing Storing Storing Setpoints Setpoints Setpoints Setpoints This command can store setpoints with reference the remote register RWw0000 to RWw000B 1 Set a material code to the upper side 8 bits of the remote register RWw0001 that is in hexadecimal numbers 2 Set zero to the parameter that is not used 3 Turn on the request flag RY0000 after storing ...

Page 19: ... 57 in the storing command RWw000E 2 Turn off the Read Write selection RY0003 3 Set the kind of data to the command code RWw000E 4 Set data to the command register RWw000C RWw000D Request flag to store setpoint RY0000 Setpoints RWw0000 to RWw000B Reply flag to store setpoints RX0000 Step 3 Step 4 Command request flag RY0002 Command data reply RWr000C RWr000D Read Write reply RX0003 Read Write sele...

Page 20: ...or Detection Flag Error Detection Flag 1 When an error is detected the remote READY flag RX007B is turned off and the error status flag RX007A turn off to inform of the error 2 The master unit requests to reset the error with the error reset request flag RY007A CPU normal operation flag RX0006 0 5 1sec Remote READY flag RX007B Error status flag RX007A Error reset request flag RY007A Kind of error ...

Page 21: ...key in weighing mode Select the menu check using the key and the ENTER key Select menu Option and the OP 20 slot To select the kind of data The key or key of RX RY RWr RWw To select an I O No or register No The key or key To exit the mode The ESC key To return to weighing mode 123kg ST RX 00F 000 BUF 0E0 1 01001000 11011011 b BR RY 00F 000 BUF 160 4 01001000 11011011 b Remote input output and Remo...

Page 22: ...Page 20 AD 4402 20 MEMO ...

Page 23: ...ページ 1 Blank page ...

Page 24: ...WYabWdZh RWn X_d Zed jh_d hh MWga X_d Zed Lmed LS25 2AT Qd_i Z H_d Zec P b f ed U55V 2346 661531 CWm U55V 2346 661596 x39708 1063 44513 gd g OigW 75 71548 CgWda jgi0JW_d 61 DBNJ KT P b f ed U5 V 7 618 2128 CWm U5 V 7 618 3165 tqv w u s vs 43 A l Oig i P XWgied Oeji jhigWb_W 6142 QOPN IF P b f ed U72V 9 9463 4144 CWm U72V 9 9463 851 tqv z wt 575 32 9i Cbeeg JWd WiiWd bZ 47 3 Te_Ze Zed Tejd Z jd fe ...

Reviews: