Ancona WPD430 User Instructions Download Page 7

This range hood is factory set for venting through the roof or wall.

Vent work can terminate either through the roof or wall.  To vent through a wall, a 90° elbow is needed.

IMPORTANT:

 

NEVER  exhaust  air  or  terminate  duct  work  into  spaces  between  walls,  crawl  spaces,  ceiling,

attics or garages.  All exhaust must be ducted to the outside.

WARNING - TO REDUCE RISK OF FIRE, USE METAL/ALUMINUM DUCT WORK ONLY

 

Fasten all connections with sheet metal screws and tape all joints with certified aluminum or foil tape.

Please check the building codes in your city to learn which tape product is recommended

 

Use caulking to seal exterior wall or roof opening around the cap.

VENTING METHODS:

TOP VENTING WALL EXHAUST

TOP VENTING ROUGH EXHAUST

Summary of Contents for WPD430

Page 1: ...RTANT SAFETY INSTRUCTIONS Carefully read the following important information regarding installation safety and maintenance Keep these instructions for future reference MODEL 2017 03 13 MAAN1192 01 WPD...

Page 2: ...on Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society of Heating Refrigeration...

Page 3: ...use smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings b Always trun hood ON when cooking at high heat or when flambeing food i e Crepes Suzette Cherries Jubilee...

Page 4: ...PARTS SUPPLIED...

Page 5: ...uired for gas stove tops It is recommended that the range hood be vented vertically through the roof through 6 15 3 cm or bigger round metal aluminum vent work The size of the vent should be uniform U...

Page 6: ...nd as far apart between two 2 as possible Minimum mount height between stove top to hood bottom should be no less than 24 inch for electric cook tops and minimum of 30 inch for gas stove tops and no h...

Page 7: ...ceiling attics or garages All exhaust must be ducted to the outside WARNING TO REDUCE RISK OF FIRE USE METAL ALUMINUM DUCT WORK ONLY Fasten all connections with sheet metal screws and tape all joints...

Page 8: ...pper cable UL CSA listed strain relief must be provided at each end of the power supply cable Use only with range hood cord connection kits that have been investigated and found acceptable for use wit...

Page 9: ...ood prevent debris from entering the vent opening Determine and mark the center line on the ceiling or wall where the range hood will be installed Make sure there is proper clearance within the ceilin...

Page 10: ...f you require longer chimney flue to reach your ceiling please contact vendor Step 2 Installing the hood mounting bracket The range hood will be installed on top of this bracket See Figure 1 Using ref...

Page 11: ...ge hood to the wall CAUTION Make certain the range hood is secure before releasing Remove the protective coating from the inner chimney Carefully slide the inner chimney down into the outer chimney Us...

Page 12: ...back of the hood Push the button on handle of the filter Release the handle once the filter fits into a resting position Repeat to install all filters Step 7 Test hood Turn power On in control panel...

Page 13: ...and off Powersettings o Press the button once and the motor starts to operate at Low speed o Press the button again and the motor will reach Medium speed o Press the button once more and the motor wi...

Page 14: ...as bulb legs may break off See Fig 9 3 Turn the bulb counter clockwise as you continue to press inward Release your pressure on the lamp when it won t turn any farther Gently pull the bulb straight ou...

Page 15: ...per Chimney Bracket Lower Chimney Bracket Mounting Bracket Hook 5 1 8 13 cm 1 3 8 3 5 cm 8 21 32 22 cm 8 5 8 21 9 cm 5 1 8 13 cm 7 7 8 20 cm 1 3 8 3 5 cm 7 7 8 20 cm 3 15 16 10 cm 3 15 16 10 cm 8 21 3...

Page 16: ...D DIAGRAMS 225 mm 173mm 6 81 8 77 223mm 8 85 1 37 35mm 19 68 500mm 29 40 747mm 400 790 mm 15 74 31 10 The range hood can reach a 9 ceiling if installed at 31 from cooktop Height of range hood 26 41 3...

Page 17: ...Check that the duct sized used is at least 6 or 3 1 4 x 10 Range hood WILL NOT function efficiently with insufficient duct size For example 7 duct over 6 hole and loosely secured Check if duct is clog...

Page 18: ...hook plate 13 power cord 12 body assembly including shell lamp plate top plate wrap angle bracket of lamp plate 11 mechanical switch box 10 mechanical switch 9 bracket ofmechanical switch box 8 GU10...

Page 19: ...Number of Motor Fan Type Control Type Filtration Type Illumination Venting Size Stainless steel 120V 60Hz USA Canada standard CUL Certified 3 levels Radio frequency interference protected Single motor...

Page 20: ...on Description 1 2 3 4 5 Electrical box cover PCB Capacitor Electrical box base Electrical box bracket No No Description Description 1 2 3 4 5 Blower Wind Wheel Nut Wind Wheel Motor Incabloc Rubber 6...

Page 21: ...T use corrosive or abrasive detergent e g Comet Power Scrub EZ Off oven cleaner or steel wool scoring pads which will scratch and damage the stainless steel surface For heavier soil use liquid degreas...

Reviews: