background image

Vent/Damper 
Mounting Screws

Vent/Damper 
Mounting Screws
(4pcs)

4

Summary of Contents for B428 28"

Page 1: ...TANT SAFETY INSTRUCTIONS Carefully read the following important information regarding installation safety and maintenance Keep these instructions for future reference MODEL B428 28 in 8 12 201 MAAN 13...

Page 2: ...erican Society of Heating Refrigeration and Air Conditioning Engineers ASHRAE and other local code authorities Before servicing or cleaning unit switch power OFF at service panel and lock service pane...

Page 3: ...3...

Page 4: ...Vent Damper Mounting Screws Vent Damper Mounting Screws 4pcs 4...

Page 5: ...ce of to 0 is recommended between stove top and the bottom of range hood 0 minim m is re ired for gas stove tops t is recommended that the range hood be vented vertically thro gh the roof thro gh 6 1...

Page 6: ...6...

Page 7: ...7...

Page 8: ...8...

Page 9: ...9...

Page 10: ...Fig 2 Step 2 Preparing the cabinet Measure and cut opening at bottom of the cabinet to fit the motor box of the range hood See Fig 1 Measure and cut a hole in the top of cabinet to fit the duct tube S...

Page 11: ...ke sure this is done by a qualified electrician in accordance with all applicable national and local electrical codes Before connecting wires switch power off at service panel and lock service panel t...

Page 12: ...Step 6 Finishing installation INSTALLATION To install the filters follow the following steps 12...

Page 13: ...CONTROL PANEL OPERATION 13 Volume up Volume down Timer Light...

Page 14: ...ond hand onto the surface of the light bulb See Fig 6 Gently turn the lightbulb counter clockwise to loosen and unlock lightbulb from socket Once unlocked the lightbulb should come out freely Installi...

Page 15: ...MEASUREMENTS AND DIAGRAMS 19 1 2 49 5 cm 1 0 1 8 2 5 7 C M 2 1 2 6 cm 27 1 2 69 8 cm 26 66 cm 15 1 1 4 26 cm 11 1 2 29 cm...

Page 16: ...wall heck that the d ct si ed sed is at least 6 ange hood NO f nction efficiently with ins fficient d ct si e For e ample 7 d ct over 6 hole and loosely secured heck if d ct is clogged or if damper n...

Page 17: ...17...

Page 18: ...Speed Control 3 Levels Airflow L M H 420 CFM Noise Level L M H Number Of Motors Single Motor Motor Type Single Chamber Quiet Fan Type Centrifugal Squirrel Cage Control Type Electronic Control Filtrat...

Page 19: ...Grid Blower Impeller Motor 19...

Page 20: ...OT use corrosive or abrasive detergent e g Co et ower Scrub E Off oven cleaner or steel wool scoring pads which will scratch and da age the stainless steel surface For heavier soil use li uid degrease...