Mechanical Installation
ANCA Motion
D-000129 Rev 09
41
4
Figure 4-8: Duct entry view
A suitable fan module kit to mount on the duct end can be supplied by ANCA Motion. See
The two fans should be fitted inside the duct end as per
and sealed to maximise air flow.
For installations using external cabinet air (see
4.3.4 Heatsink Cooling with External Cabinet Air Using Duct
), the inlet fans can be mounted on inside of the cabinet wall, with outlet protection grills on the
outside. The fan cut-out is shown in
For installations using internal cabinet air (see
4.3.5 Heatsink Cooling with Internal Cabinet Air Using Duct Mount
), the fans can be mounted on duct end plate with fan cut-out is shown in
The outlet protection
grills are optional.
An example of the fan kit, fan cut-out, and cut-out positioning relative to cooling duct is shown in
Figure 4-9: AMD5x fan and duct positioning, and fan cut-out