background image

USER MANUAL FOR WTP-25 POOL FILTER 

 

5

9-

 

+

Set the clock and increase time. 

10-

 

A/M

The switch of manual mode and automatic mode.

 

11-

 

-

Set the clock and decrease time.   

 

. Instructions for manual operation: 

‹

 

Press “

ON/OFF

” key to make the power on and the control system is ready to run.

 

‹

 

Press “

A/M

” to start the manual mode (the indicator light on it is off). In manual mode, press 

ON/OFF

” key to turn on and turn off the circulating pump.   

‹

 

Press the “

LAMP

” key to make the underwater light on (the indicator light on it will be on).

 NOTE

Press all the above keys again to make the functions off.   

 

. Instructions for automatic operation: 

‹

 

Press “

ON/OFF

” key to make the power on and the control system is ready to run. 

‹

 

Press “

A/M

” to start the automatic mode (the indicator light on it will show RED). 

‹

 

In automatic mode, when the current time is during the period of set time, the indicator light on 

T/ON

” will be on; when the current time is out of the period of set time, the indicator light on 

T/OFF

” will be on; 

‹

 

When the manual mode is cancelled, the circulation system will be controlled by the preset time in 
each use. 

1.

 

Set system clock:

 Long press

 “A/M”

 key for 3 seconds and loosen the hand, the panel will display 

system clock time and hour/minute digit flashes: Press 

“+”“-”

 to adjust the clock time. It will store 

and return to the previous working status after flashing 3 seconds. 

 
2.

 

Setting the first operating period: 

in automatic mode, press “

T1

” key to starting setting the first on 

operating period.   

 

¾

 

Press “

T/ON

” key (the indicator light on it will be on) within 3 seconds after press “

T1

” key to start 

setting the starting time for the first period. Press “

” and “

” keys to adjust the minute (the minute 

number on LED screen will flash) within 3 seconds after press “

T/ON

” key. No action within 3 

seconds, the minute number will stop flashing and be saved automatically. If need to adjust the hour, 
press “

T1

” key again within 3 seconds to start setting it. Press “

” and “

” keys to adjust the hour 

(the hour number on LED screen will flash). No action within 3 seconds, the minute number will stop 
flashing and be saved automatically.   

¾

 

Press “

T/OFF

” key (the indicator light on it will be on) to start setting the end time within 3 seconds. 

Press “

” and “

” keys to adjust the minute (the minute number on LED screen will flash). No 

action within 3 seconds, the minute number will stop flashing and be saved automatically. If need to 
adjust the hour, press “

T1

” key again with 3 seconds to start setting the hour. Press “

” and “

” 

keys to adjust the hour (the hour number on LED screen will flash). No action within 3 seconds, the 
minute number will stop flashing and be saved automatically. 

 

PLEASE SET T2 AND T3 OPERATING PERIOD LIKE ABOVE OPERATION. 

  

REMARK: if no need to set the time in any of the 3 periods, just set the time to “zero” in that period to 
avoid it. 

 
 

Cautions before first using: 

‹

 

Before running the device for the first time, turn on the ball valve of the pipe and fill water until the 
equipment box pipe are full of water and then turn off the ball valve. 

‹

 

When it is ready to start running, press the

 “ON/OFF”

 key on control panel for several times until 

the circulation pump can work normally because there may be some air inside the pipes and pump for 
first runnin

g.  

 

Reviews: