background image

INSTALLATION & 

OPERATION MANUAL

PWS610R Rack Mount
AC/DC Power Supply

8128 River Way, Delta B.C. V4G 1K5  Canada  T. 604.946.9981  F. 604.946.9983  TF. 800.668.3884  (US/CANADA)

www.analyticsystems.com

An ISO9001 and AS9100 Registered Company 

Battery Chargers 

 Inverters 

 Power Supplies 

 Voltage Converters

Summary of Contents for PWS610R

Page 1: ...unt AC DC Power Supply 8128 River Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 800 668 3884 US CANADA www analyticsystems com An ISO9001 and AS9100 Registered Company Battery Chargers...

Page 2: ...Copyright 2005 2014 Analytic Systems Ware 1993 Ltd...

Page 3: ...roperly installed and grounded in accordance with al local codes and ordinances DANGER Never alter AC cord or plug provided if it will not fit outlet have proper cord installed by a qualified electric...

Page 4: ...or below the standard output voltage An output overvoltage crowbar circuit protects devices connected to the converter The PWS610 Series Power Supply supplies 12 24 32 or 48 VDC from a 110 or 220 VAC...

Page 5: ...utput Case 500 VDC 1500Vdc 48 V Out Dimensions 19 0 x 13 5 x 3 5 in 48 3 x 34 3 x 8 9 cm Clearance 1 Inch 2 5 cm all around Material Marine Grade Aluminum Finish Black Powder Epoxy Fastenings 18 8 Sta...

Page 6: ...opriate junction box The maximum current draw from a 110 VAC source is 8 1 amps so a 10 amp circuit breaker should be used in the circuit panel For a 220 VAC source 4 amps is the maximum current draw...

Page 7: ...piece of 14 AWG red wire to each positive output terminal Connect all the positive wires to a distribution bus or connect them together and then connect from the common point to the load using the cor...

Page 8: ...operation of the unit OVERTEMP Indicates that the voltage converter is running too hot because Too much power is being drawn turn off or unplug some devices The voltage converter is located in a poor...

Page 9: ...9...

Page 10: ...p Components Conformal Dipping and RTV Compound Option w Wide Temperature Operation 40 to 55 C incl Option SM High Voltage Protection on the DC Input Side Option d Paralleling Diodes Option FI Forklif...

Page 11: ...ng will incur additional charges and are the responsibility of the Purchaser 6 Analytic Systems reserves the right to void the warranty if a Labels identification marks or serial numbers are removed o...

Page 12: ...Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 800 668 3884 US CANADA www analyticsystems com An ISO9001 and AS9100 Registered Company Battery Chargers Inverters Power Supplies Voltage...

Reviews: