![Analytic Systems PWS1000R series Installation & Operation Manual Download Page 8](http://html1.mh-extra.com/html/analytic-systems/pws1000r-series/pws1000r-series_installation-and-operation-manual_2940552008.webp)
8
Output Adjustment
The unit has an adjustment potentiometer to allow up to +/- 0.5V adjustment of the output
voltage. This potentiometer is accessed through a small hole on the front plate of the voltage
converter. As shipped from the factory, the unit is preset for a voltage of 13.6, 27.2, 36.3 or
54.4VDC. If you wish to adjust this voltage reach in with a very small flat blade screwdriver
to rotate the potentiometer. Clockwise increases the output voltage and counter clockwise
decreases it.
Meters
The unit comes equipped with a digital volt ammeter. The meter shows simultaneous voltage
and current on either of the two output terminals. A toggle switch permits selection between
the output terminals. The meter features bright red LED readouts to permit easy monitoring
from many feet or meters away.