IMPORTANT & SAFETY INSTRUCTIONS

1.  SAVE THESE INSTRUCTIONS — This manual contains important safety and operating 

instructions for power supply.

2.  Do not expose power supply to rain or snow.
3.  Use of an attachment not recommended or sold by the power supply manufacturer may 

result in a risk of fire, electric shock, or injury to persons.

4.  Do not disassemble power supply; take it to a qualified serviceman when service or 

repair is required.  Incorrect reassembly may result in a risk of electric shock or fire.

5.  To reduce risk of electric shock, unplug power supply from outlet before attempting any 

maintenance or cleaning.  Turning off controls will not reduce this risk.

6.  Never place marine power supply directly above battery; gases from battery will corrode 

and damage power supply.

7.  Never allow battery acid to drip on power supply when reading gravity or filling battery.
8.  O/P CONNECTION PRECAUTIONS

Connect and disconnect DC output connections only after setting the power supply 

switch to the off position.

GROUNDING AND AC POWER CORD CONNECTION INSTRUCTIONS  — 

The plug must 

be plugged into an outlet that is properly installed and grounded in accordance with al local 

codes and ordinances.

DANGER — 

Never alter AC cord or plug provided — if it will not fit outlet, have proper cord 

installed by a qualified electrician.  Improper connection can result in a risk of an electric 

shock.

Analytic Systems does not recommend the use of the PWS1000 Series Power Supplies in life 

support applications where failure or malfunction of this product can be reasonably expected 

to cause failure of the life support device or to significantly affect its safety or effectiveness.  

Analytic Systems does not recommend the use of any of its products in direct patient care.

Examples of devices considered to be life support devices are neonatal oxygen analyzers, 

nerve stimulators (whether used for anesthesia, pain relief, or other purposes), autotransfu-

sion devices, blood pumps, defibrillators, arrhythmia detectors and alarms, pacemakers, 

hemodialysis systems, peritoneal dialysis systems, neonatal ventilator incubators, ventilators 

for both adults and infants, anesthesia ventilators, and infusion pumps as well as any other 

devices designated as “critical” by the U.S. FDA.

Summary of Contents for PWS1000

Page 1: ...00 Power Supply 8128 River Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 800 668 3884 US CANADA www analyticsystems com An ISO9001 and AS9100 Registered Company Battery Chargers Inverters Power Supplies Voltage Converters ...

Page 2: ...Copyright 2005 2013 Analytic Systems Ware 1993 Ltd ...

Page 3: ...ND AC POWER CORD CONNECTION INSTRUCTIONS The plug must be plugged into an outlet that is properly installed and grounded in accordance with al local codes and ordinances DANGER Never alter AC cord or plug provided if it will not fit outlet have proper cord installed by a qualified electrician Improper connection can result in a risk of an electric shock Analytic Systems does not recommend the use ...

Page 4: ...or 220 VAC power source High quality digital meters can be added factory option to allow monitoring of charging current and charging voltage Other output voltages up to 72 volts are also available by special order Specifications Input Voltages Nominal ip 110Vac 220Vac Actual 90 130Vac 180 260Vac Input Amps max 13 2 12V 17 24 32 48V 6 6 12V 8 5 24 32 48V Input Fuse slow blow MDA 20 12V MDA 25 24 32...

Page 5: ... V4G 1K5 Canada p 604 946 9981 f 604 946 9983 tf 800 668 3884 US Canada www analyticsystems com analyticinfo analyticsystems com Revised January 2014 Specifications subjects to change without notice Installation MOUNTING Mount the unit in a DRY location Allow at least 4 inches of clearance around the heat sink fins for adequate cooling POWER CONNECTION The unit is supplied with a 5 foot power cabl...

Page 6: ...t When you are done replace the cover plate and securely tighten the screws All connections should be made inside an appropriate junction box The maximum current draw from the 110 VAC supply is 14 6 amps so a 20 amp circuit breaker should be used in the circuit panel and for a 220 VAC supply 7 3 amps is the maximum current draw so a 10 amp circuit breaker should be used in the circuit panel to fee...

Page 7: ...ver and locate J10 It will be next to the relay K1 as is shown in the above diagram Simply move the jumper to the desired position as is shown in the above diagram Replace the cover and re install the eight cover screws Reconnect the unit to the power and load s Dry Contact Relay Meters High quality digital meters can be added to the charger factory installed only Both outputs can be monitored for...

Page 8: ...cating all the diagnostic indicators and audible alarm REMOTE CONNECTOR This connector is located on the side of the unit Important To prevent the possibility of High Voltage Electrical Shock do not power up the Power Supply unless all wiring from the unit to the remote is securely connected Do not remove the dust cover from the DB 9 connector if the remote is not being used Remote Control Option ...

Page 9: ...e LOW INPUT Indicates that the input voltage is below normal because The input voltage is not in the correct range for proper operation of the unit OVERTEMP Indicates that the Battery Charger is running too hot because Too much power is being drawn turn off or unplug some devices The Battery Charger is located in a poorly ventilated area OVERLOAD Indicates that the load it trying to draw to much c...

Page 10: ...10 ...

Page 11: ...ing will incur additional charges and are the responsibility of the Purchaser 6 Analytic Systems reserves the right to void the warranty if a Labels identification marks or serial numbers are removed or altered in any way b Our invoice is unpaid c The defect is the result of misuse neglect improper installation environmental conditions non autho rized repair alteration or accident 7 No refund of t...

Page 12: ... Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 800 668 3884 US CANADA www analyticsystems com An ISO9001 and AS9100 Registered Company Battery Chargers Inverters Power Supplies Voltage Converters ...

Reviews: