Analytic Systems Pure Sine 300 Installation And Operation Manual Download Page 4

 

3

IMPORTANT SAFETY INSTRUCTIONS 

 

 
1) 

SAVE THESE INSTRUCTIONS

 — This manual contains important safety and 

operating instructions for inverter. 
 
2) Do not expose inverter to rain or snow. 
 
3) Use of an attachment not recommended or sold by the inverter manufacturer may 
result in a risk of fire, electric shock, or injury to persons. 
 
4) Do not disassemble inverter; take it to a qualified serviceman when service or repair 
is required.  Incorrect reassembly may result in a risk of electric shock or fire. 
 
5) To reduce risk of electric shock, unplug inverter from outlet before attempting any 
maintenance or cleaning.  Turning off controls will not reduce this risk. 

 

6) Never place inverter directly above battery; gases from battery will corrode and 
damage inverter. 
 
7) Never allow battery acid to drip on inverter when reading gravity or filling battery. 

 
 

GROUNDING AND AC POWER CORD CONNECTION INSTRUCTIONS

  — Inverters should 

be grounded to reduce risk of electric shock.  Inverter is equipped with electric receptacles 
capable of accepting an equipment-grounding conductor and a grounding plug. 

 

Analytic Systems

 does not recommend the use of the IPS300 Series Pure Sine Inverters in life 

support applications where failure or malfunction of this product can be reasonably expected to 
cause failure of the life support device or to significantly affect its safety or effectiveness.  

Analytic Systems

 does not recommend the use of any of its products in direct patient care. 

 
Examples of devices considered to be life support devices are neonatal oxygen analyzers, 
nerve stimulators (whether used for anesthesia, pain relief, or other purposes), autotransfusion 
devices, blood pumps, defibrillators, arrhythmia detectors and alarms, pacemakers, 
hemodialysis systems, peritoneal dialysis systems, neonatal ventilator incubators, ventilators for 
both adults and infants, anesthesia ventilators, and infusion pumps as well as any other devices 
designated as "critical" by the U.S. FDA. 
 

DANGER:

 

Never alter AC cord or plug provided — if it will not fit outlet, have proper cord 

installed by a qualified electrician.  Improper connection can result in a risk of an electric 
shock.

 

Summary of Contents for Pure Sine 300

Page 1: ...Pure Sine 300 Installation and Operation Manual 220 VAC Version Shown...

Page 2: ...the same as household AC Crystal controlled for precise frequency 0 01 Hz 300 Watts output power sufficient for a complete computer workstation including processor monitor and printer except laser pr...

Page 3: ...ral Efficiency 80 maximum output Temp Range 0 40 C maximum output Isolation 500 VDC Input to Case 1500 VDC Input to Output Output to Case Dimensions 10 7 x 7 7 x 5 2 in 27 2 x 19 6 x 13 2 cm Clearance...

Page 4: ...ipped with electric receptacles capable of accepting an equipment grounding conductor and a grounding plug Analytic Systems does not recommend the use of the IPS300 Series Pure Sine Inverters in life...

Page 5: ...ted inside the unit POWER CONNECTION Use a voltmeter to measure the input voltage to ensure the voltage of the battery is within the Input Voltage range printed on the front of the unit The unit is su...

Page 6: ...e receptacles POWER SAVE The Power Save feature allows the user to set the level at which the unit goes into the Power Save mode The Power Save mode adjustment is accessed on the front of the unit A s...

Page 7: ...r is being drawn turn off or unplug some devices SHORT CIRCUIT Indicates that a short circuit has occurred at the inverter output Turn off the inverter Disconnect all devices from the inverter and cle...

Page 8: ...not activated 7 If the unit cycles on and off check and see if the standby light comes on when the unit is off If so the Power Save mode is set too close to the recovery 40 watts load Adjust the Power...

Page 9: ...TIONAL A remote control panel may be connected to the inverter using a 9 pin D connector which attaches to the front panel of the inverter The remote control panel and D connector are part of the remo...

Page 10: ...9 This page left intentionally blank...

Page 11: ...10 This page left intentionally blank...

Page 12: ...o remedy the defect after having a reasonable number of opportunities to do so 5 Warranty service shall be performed only by the Warrantor Any attempt to remedy the defect by anyone else shall render...