8128 River Way, Delta B.C. V4G 1K5 Canada T. 604.946.9981 F. 604.946.9983 TF. 1.800.668.3884 (US/CANADA)
www.analyticsystems.com
IVS1000
Pure Sinewave Inverter
Page 1: ...Installation Operation Manual 8128 River Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 1 800 668 3884 US CANADA www analyticsystems com IVS1000 Pure Sinewave Inverter...
Page 2: ...2 Copyright 2005 2013 Analytic Systems Ware 1993 Ltd...
Page 3: ...er is equipped with electric receptacles capable of accepting an equipment grounding conductor and a grounding plug DANGER Never alter AC cord or plug provided if it will not fit outlet have proper co...
Page 4: ...is capable of sup plying a significantly higher current than is actually required It is preferable to turn on the inverter first and connect the load after the inverter is already running Input Wire...
Page 5: ...no damage occurs whilst reverse polarizing the input On some models the internal input fuse may blow when reverse polarity occurs Input and output filtering All IVS1000 series inverters have a double...
Page 6: ...mum 0 5 Load Regulation Maximum 6 from 10 load to full load Output Noise High frequency ripple is better than 500 mVrms 20 MHz BW GENERAL Temperature Drift 0 05 per C over operating temperature range...
Page 7: ...ional charges and are the responsibility of the Purchaser 5 Analytic Systems reserves the right to void the warranty if a Identification marks or serial numbers are removed or altered in any way b Our...
Page 8: ...y other consequential or resulting damage which may be claimed to have been incurred through the use or sale of the equipment including any possible failure of malfunction of the equip ment or part th...