8
9
AC Connections
BEFORE MAKING ANY CONNECTIONS, MAKE THE POWER SWITCH IS OFF.
AC OUTPUT CONNECTIONS
This unit is equipped with two AC Output connections.
• A standard NEMA 5-15 AC receptacle is provided for connection. This connection is
protected by a Thermal Carling 15A circuit breaker.
• A 30 amp, 250V rated CSA/UL approved Phoenix VDFK terminal block is also provided for
wiring to a distribution panel. It is wired as follows:
CAUTION
:
Do not apply AC voltage to the output connection.
This will damage the Inverter and will not be covered under warranty.
CAUTION
:
This terminal block is NOT protected by a circuit breaker.
Each device wired to the distribution panel connected to the terminal block must have its
own circuit breaker. Ensure that the total average load of all the devices does not exceed the
continuous current rating of the unit.
Block Color
Function
Grey
AC Neutral
Green / Yellow
AC Ground
Black
AC Hot
Summary of Contents for IPSi2400 Series