Specifications

Safety Considerations 

WARNING:  

The FCA250 & FCA500 series frequency converters generate 115VAC (or 230VAC) power – the same voltage 

coming out of a standard wall outlet.  This voltage can be hazardous and has to be treated with the same cau-

tion as with a regular electrical outlet.

As with any other electrical equipment, the frequency converter must be protected from water and moisture 

at all times.

INPUT
Input Voltage:

115/230 VAC +/- 20%, auto-ranging, 47 to 410Hz

Input Protection:

Inrush current limiting & thermal fuse

Input Isolation:

2250 Vdc input to output, input to chassis & output to chassis

RFI Suppression:

Meets requirements of FCC 20780 Class B and EN55022 Class B con-

ducted emissions as a minimum

OUTPUT

Output Voltage / Current:

115 VAC / 60 Hz / 2.1 Amp continuous  (250 Watts)

230 VAC / 50 Hz / 1.05 Amp continuous or 

any combination including frequency up to 400Hz

Wave Form:

Sinusoidal

Total Harmonic Distortion:

Better than 5% at full load

Line Regulation:

Maximum 0.5%

Load Regulation:

Maximum ± 6% from 10% load to full load

GENERAL
Temperature Drift:

0.05% per º C over operating temperature range

Operating Temp. Range:

0º C to +50º C for full specification (no fan)

Humidity:

5 - 95 % non-condensing

Output Protection:

Current limiting with short-circuit protection.  Thermal shutdown with 

automatic recovery in case of continuous overload or insufficient airflow

Output Overload Protection:

Hiccup at 300 W

Output Over-voltage Protection: By internal supply voltage limiting at 120% V out, nominal level
Load Crest Factor:

Maximum 2.5 at 90% load

Efficiency:

Minimum 78% at full load

Cooling:

By convection / conduction

Input Connection:

Screw-type terminal block

Output Connection:

Standard AC Receptacle  (North American Type)

Package Size / Weight:

5.0 x 5.3 x 15.5 Enclosed case, 9 pounds ( 4.1 kg )

Summary of Contents for FCA250

Page 1: ...Installation Operation Manual FCA250 FCA500 FREQUENCY CONVERTER 8128 River Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 1 800 668 3884 US CANADA www analyticsystems com...

Page 2: ...2 Copyright 2005 2013 Analytic Systems Ware 1993 Ltd...

Page 3: ...ng battery GROUNDING AND AC POWER CORD CONNECTION INSTRUCTIONS The frequency converter should be grounded to reduce risk of electric shock The frequency converter is equipped with electric recep tacle...

Page 4: ...otection The frequency converter has a number of protection circuits designed to provide full electronic protection Grounding The input can be either positively or negatively grounded or may be left f...

Page 5: ...atts 230 VAC 50 Hz 1 05 Amp continuous or any combination including frequency up to 400Hz Wave Form Sinusoidal Total Harmonic Distortion Better than 5 at full load Line Regulation Maximum 0 5 Load Reg...

Page 6: ...ll specification no fan Humidity 5 95 non condensing Output Protection Current limiting with short circuit protection Thermal shutdown with automatic recovery in case of continuous overload or insuffi...

Page 7: ...ing will incur additional charges and are the responsibility of the Purchaser 5 Analytic Systems reserves the right to void the warranty if a Identification marks or serial numbers are removed or alte...

Page 8: ...ny other consequential or resulting damage which may be claimed to have been incurred through the use or sale of the equipment including any possible failure of malfunction of the equipment or part th...

Reviews: