Analytic Systems BCD605 Installation & Operation Manual Download Page 10

10

Limited Warranty

1.  The equipment manufactured by Analytic Systems Ware (1993) Ltd. (the “Warrantor”) is war-

ranted to be free from defects in workmanship and materials under normal use and service.

2.  This warranty is in effect for:

a. 

3 Years from date of purchase by the end user for standard products offered in our 

catalog.

b.  2 Years from date of manufacture for non-standard or OEM products

c. 

1 Year from date of manufacture for encapsulated products.

3.  Analytic Systems will determine eligibility for warranty from the date of purchase shown on the 

warranty card when returned within 30 days, or

a. 

The date of shipment by Analytic Systems, or

b.  The date of manufacture coded in the serial number, or 

c. 

From a copy of the original purchase receipt showing the date of purchase by the user.

4.  In case any part of the equipment proves to be defective, the Purchaser should do the following:

a. 

Prepare a written statement of the nature of the defect to the best of the Purchasers 

knowledge, and include the date of purchase, the place of purchase, and the Purchas-

ers name, address and telephone number.

b.  Call Analytic Systems at 800-668-3884 or 604-946-9981 and request a return material 

authorization number (RMA).

c. 

Return the defective part or unit along with the statement at the Purchasers expense 

to the Warrantor; Analytic Systems Ware (1993) Ltd., 8128 River Way, Delta, B.C., 

V4G 1K5, Canada.

5.  If upon the Warrantor’s examination the defect proves to be the result of defective material or 

workmanship, the equipment will be repaired or replaced at the Warrantor’s option without 

charge, and returned to the Purchaser at the Warrantor’s expense by the most economical means. 

Requests for a different method of return or special handling will incur additional charges and 

are the responsibility of the Purchaser.

6.  Analytic Systems reserves the right to void the warranty if:

a. 

Labels, identification marks or serial numbers are removed or altered in any way.

b.  Our invoice is unpaid.

c. 

The defect is the result of misuse, neglect, improper installation, environmental condi-

tions, non-authorized repair, alteration or accident.

7.  No refund of the purchase price will be granted to the Purchaser, unless the Warrantor is unable 

to remedy the defect after having a reasonable number of opportunities to do so.

8128 River Way, Delta B.C. V4G 1K5 Canada   T. 604.946.9981    F. 604.946.9983     TF. 1.800.668.3884  (US/CANADA)

Summary of Contents for BCD605

Page 1: ...Installation Operation Manual BCD605 DC Battery Charger 8128 River Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 1 800 668 3884 US CANADA www analyticsystems com...

Page 2: ...2 Copyright 2005 2013 Analytic Systems Ware 1993 Ltd...

Page 3: ...DURING NORMAL BATTERY OPERA TION FOR THIS REASON IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE SERVICING EQUIPMENT IN THE VICINITY OF THE BATTERY YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EX...

Page 4: ...TION i Never place battery charger directly above battery gases from battery will corrode and damage converter ii Never allow battery acid to drip on battery charger when reading gravity or filling ba...

Page 5: ...indicators for low input voltage low output voltage and over temperature Safety features include reverse input protection over temperature shutdown current limiting short circuit protection with autom...

Page 6: ...charging current 10 5 13 6 x 40 30 8 amps Specifications Model BCD605 12 12 BCD605 12 24 Input Volts DC 10 5 14 10 5 28 Input Amps max 50 Output Volts DC 13 6 0 5 V 27 2 0 5 V Charging Amps 42 21 Outp...

Page 7: ...n 15 volts Note that the current specifications are for input current To obtain the maximum output current capability at any given input voltage use the following formula Output Current Input Volts Ou...

Page 8: ...t rating the fuse will blow If the fuse blows with no load connected check that the power leads are connected to the battery with the correct polarity if they are then the unit is damaged and must be...

Page 9: ...tely as well as duplicating all the diagnostic indicators and audible alarm REMOTE CONNECTOR This connector is located on the side of the unit Important To prevent the possibility of High Voltage Elec...

Page 10: ...urchas ers name address and telephone number b Call Analytic Systems at 800 668 3884 or 604 946 9981 and request a return material authorization number RMA c Return the defective part or unit along wi...

Page 11: ...tability fitness for the ordinary purposes for which such goods are used or fitness for a particular purpose or any other obligations on the part of the Warrantor or its employees and representatives...

Reviews: