Analytic Systems BCD305-12-24 Installation & Operation Manual Download Page 1

INSTALLATION & 

OPERATION MANUAL

BCD305 SERIES 
DC Battery Charger 

8128 River Way, Delta B.C. V4G 1K5  Canada  T. 604.946.9981  F. 604.946.9983  TF. 800.668.3884  (US/CANADA)

www.analyticsystems.com

An ISO9001 Registered Company 

Battery Chargers 

 Inverters 

 Power Supplies 

 Voltage Converters

Summary of Contents for BCD305-12-24

Page 1: ...SERIES DC Battery Charger 8128 River Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 800 668 3884 US CANADA www analyticsystems com An ISO9001 Registered Company Battery Chargers Inverte...

Page 2: ...ctly above battery gases from battery will corrode and damage battery charger 6 Never allow battery acid to drip on to the battery charger 1 WARNING RISK OF EXPLOSIVE GASES i WORKING IN VICINITY OF A...

Page 3: ...diately with soap and water If acid enters eye immediately flood eye with running cold water for at least 10 v NEVER smoke or allow a spark or flame in the vicinity of a battery vi Be extra cautious t...

Page 4: ...OF CONTENTS Front Cover Product Photo and Title Product warnings and advisories Table of Contents Description Overview of product Box Contents Operation instructions Mounting Instructions Connection...

Page 5: ...ure shutdown current limiting short circuit protection with automatic recovery input undervoltage shutdown reverse battery protection and output overvoltage crowbar Optional features include a dry con...

Page 6: ...wires as follows Red to Positive Black to Negative POWER CONNECTION Two positive output terminals and two negative output terminals are provided Connect only one wire to each terminal Note that the c...

Page 7: ...minals Operation Troubleshooting If the load exceeds the continuous rating for too long a period the internal temperature sensor will cause the unit to stop boosting the input voltage until the unit h...

Page 8: ...1 It will be next to the relay as is shown in the above diagram Simply move the jumper to the desired position as is shown in the above diagram Replace the cover and re install the four screws Reconne...

Page 9: ...Model BCD305 12 24 Input Volts DC 10 5 24 Input Amps max 30 Output Volts DC 27 2 0 5 V Charging Amps 13 Output Crowbar Output Volts x 1 3 1 Input Fuses AGC 20 x 2 Output Fuse AGC 30 x 2 Low Input Volt...

Page 10: ...rt for each unit Available as Add on to M Option J MIL810G in house tested and report for each unit Available as Add on to M Option K Synchronized Inverters L not assigned M Military Rugged Package MI...

Page 11: ...ng will incur additional charges and are the responsibility of the Purchaser 6 Analytic Systems reserves the right to void the warranty if a Labels identification marks or serial numbers are removed o...

Page 12: ...River Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 800 668 3884 US CANADA www analyticsystems com An ISO9001 Registered Company Battery Chargers Inverters Power Supplies Voltage Conve...