Specifications
* Specifications subjects to change without notice.
Input
Unit Model
BCA150
Voltage
85-265 VAC
Current
3A (Max @ 90 VAC in)
Power Factor
>0.98 at full load (>0.86 @ 400Hz)
Input Frequency
45 - 405 Hz
Noise on Input
< 50 mV
Output
Nominal Voltage
12 VDC
24 VDC
Float Voltage
13.4 ± 0.6 VDC
27.6± 1.2 VDC
Charging Current
12A
6A
Output Fuse
ATL-15
ATL-8
Duty Cycle
Continuous
Efficiency
> 90% @ Maximum Output
Charging Stages
2
Number of Battery Banks
1 or 2
Mechanical
Dimensions
8.0 in/20.3 cm Long x 8.8 in/22.4 cm Wide x 2.2 in/5.6 cm High
Clearance
1.0 in/2.5 cm all around
Weight
3.6 lb / 1.6 kg
Mounting
Wall Mount (with Drip Shield)
Material & Finish
Marine Grade Black Powdered Aluminum with 18-8 Stainless Fasteners
Connections
AC Input - 3-pin IEC320 AC Inlet (6.3mm) Tab Flange Mount
DC Output - 2x Phoenix VDFK4 Terminal Blocks (Red and Black)
Environmental and Safety
Operating Temperature Range
-25°C to +40°C @ maximum output.
Humidity
0 - 95% Relative Humidity (non-condensing) with standard conformal coating
Isolation
Input-Case & Input-Output, Output-Case: 1500VDC
Emissions
Meets FCC Part 15, Class B
Safety
Built to meet CE, UL458 and CSA 22.2.107.1
Typical Service Life
> 10 years (87,600 hrs)
Warranty