2.5.
POWER UP THE ADV7282-M EVALUATION BOARD
1.
Connect a mains cable to the 7.5 V supply cable included in the ADV7282-M evaluation kit.
2.
Connect the 7.5 V supply cable to Jumper J8 on the ADV7282-M evaluation board. When this is done correctly, LED D6 turns
on (refer to
).
3.
Connect the USB cable included in the ADV7282-M evaluation kit to the computer where you installed the DVP Eval program
and ADV7282-M script files. This cable is used to send commands from your computer to the ADV7282-M evaluation board.
4.
Connect the other end of the USB cable to Jumper J7 of the ADV7282-M evaluation board. When this is done correctly, LED D7
turns on (refer to
5.
Connect the analog video input(s) to the Ain inputs of the ADV7282-M evaluation board. Refer to
how to connect these inputs.
6.
Connect SMA cables to the MIPI CSI-2 output connectors and feed these to a sink device.
Notes:
•
The I
2
C lines to the ADV7282-M can be accessed via test points on the evaluation board. Refer to
•
Even after the ADV7282-M evaluation board is powered up, the 28.63636 MHz crystal (Y1) will not oscillate until the
ADV7282-M is programmed (refer to Section
).
2.6.
PROGRAM THE ADV7282-M EVALUATION BOARD
1.
To run the DVP Eval Latest Source application, select Start-> All Programs -> Analog Devices -> DVP Eval Latest Source 10-14-
11.
2.
Press the
Choose Board
button on the top left of the DVP Eval program window and the Board Selector window appears (refer
to
.
Figure 5. Board Selector Window of DVP Eval Program
3.
Select ADV7282M_CUST in the Rx section of the Board Selector window.
4.
Select None in the MotherBoard section.
5.
Select None in the Tx section.
6.
Press the
Load
button. A window similar to that shown in
appears.