UG-1271 

EVAL-ADGS1208SDZ

/

EVAL-ADGS1209SDZ

 User Guide 

 

Rev. 0 | Page 4 of 17 

EVALUATION BOARD HARDWARE 

POWER SUPPLIES 

Connector J1 provides access to the supply pins of th

ADGS1208

/ 

ADGS1209

V

DD

, GND, and V

SS

 on the J1 terminal block link to the 

appropriate pins on th

ADGS1208

/

ADGS1209

For dual-supply 

voltages, the evaluation board can be powered from ±15 V. For 
single-supply voltages, the GND and V

SS

 terminals must 

connect together and power the evaluation board from 12 V. 
Additionally, the SDP supplies 3.3 V to the RESET/V

L

 pin of the 

ADGS1208

/

ADGS1209

 when Link LK1 is in Position B. When 

using a method other than the SDP to control the 

ADGS1208

/ 

ADGS1209

, supply between 2.7 V and 5.5 V to the RESET/ 

V

L

 pin of the 

ADGS1208

/

ADGS1209

 via the EXT_VL screw 

terminal input on J1. LK1 must be in Position A.  

INPUT SIGNALS 

Provided are screw connectors J2, J3, and J6 to connect to both 
the source and drain pins of th

ADGS1208

/

ADGS1209

Additional Subminiature Version B (SMB) connector pads are 
available if extra connections are required. 
Each trace on the source and drain pins includes two sets of 
0603 pads, which place a load on the signal path to ground. A 
0 Ω resistor is placed in the signal path and can be replaced 
with a user defined value. The resistor, combined with the 0603 
pads, creates a simple resistor capacitor filter. 

DIGITAL OUTPUTS 

The GPOx digital outputs are accessible from Screw Connector J7 
and there are additional SMB connector footprints available if 
extra connections are required.  

LINK OPTIONS 

The EVAL-ADGS1208SDZ/EVAL-ADGS1209SDZ evaluation 
boards provide several link options that must be set at the 
required operating conditions before use.  
Table 1 describes the positioning of the links necessary for 
controlling the evaluation board via the SDP board using a PC 
and external power supplies. Table 2 describes the functions of 
these link options. 
LK1 must be in Position B to avoid damaging the SDP when 
using it in conjunction with the EVAL-ADGS1208SDZ/ 
EVAL-ADGS1209SDZ.  

Table 1. Link Options for SDP Control (Default) 

Link Number 

Option 

LK1 

LK2 

 

Table 2. Link Functions 

Link Number 

Function 

LK1  

This link selects the source of the V

L

 voltage supplied to th

ADGS1208

/

ADGS1209

 

Position A selects EXT_VL from J1. 

 

Position B selects the 3.3 V from the SDP. 

LK2 

 

This link selects how a hardware reset is performed. 

 

Position A indicates the SW1 push-button can perform a hardware reset. 

 

Position B indicates the SDP can perform a hardware reset. 

 

Summary of Contents for EVAL-ADGS1208SDZ

Page 1: ... 8 1 dual 4 1 multiplexers controlled by a serial peripheral interface SPI The SPI has robust error detection features including cyclic redundancy check CRC error detection invalid read write address detection and serial clock SCLK count error detection It is possible to daisy chain multiple ADGS1208 ADGS1209 devices together to enable the configuration of multiple devices with a minimal amount of...

Page 2: ... Photographs 3 Evaluation Board Hardware 4 Power Supplies 4 Input Signals 4 Digital Outputs 4 Link Options 4 Evaluation Board Software Quick Start Procedures 5 Installing the Software 5 Initial Setup 5 Block Diagram and Description 6 Memory Map 6 Evaluation Board Schematics and Artwork 8 EVAL ADGS1208SDZ 8 EVAL ADGS1209SDZ 13 Ordering Information 17 Bill of Materials 17 REVISION HISTORY 4 2018 Rev...

Page 3: ...EVAL ADGS1208SDZ EVAL ADGS1209SDZ User Guide UG 1271 Rev 0 Page 3 of 17 EVALUATION BOARD PHOTOGRAPHS 16732 001 Figure 1 EVAL ADGS1208SDZ 16732 002 Figure 2 EVAL ADGS1209SDZ ...

Page 4: ...gnal path to ground A 0 Ω resistor is placed in the signal path and can be replaced with a user defined value The resistor combined with the 0603 pads creates a simple resistor capacitor filter DIGITAL OUTPUTS The GPOx digital outputs are accessible from Screw Connector J7 and there are additional SMB connector footprints available if extra connections are required LINK OPTIONS The EVAL ADGS1208SD...

Page 5: ...S1208SDZ EVAL ADGS1209SDZ evaluation boards plugins appear when opening ACE INITIAL SETUP To set up the EVAL ADGS1208SDZ EVAL ADGS1209SDZ evaluation boards complete the following steps 1 Connect the EVAL ADGS1208SDZ EVAL ADGS1209SDZ evaluation boards to the SDP board and connect the SDP board to the PC via a USB cable 2 Turn on the evaluation board as described in the Power Supplies section 3 Run ...

Page 6: ...ory map correspond to the block diagram For example if the internal register bit is enabled it displays as enabled on the block diagram Bolded bits or registers represent modified values that have not been transferred to the evaluation board After clicking Apply Changes the data is transferred to the evaluation board and no longer appears as bolded Table 3 Block Diagram Functions Label Function A ...

Page 7: ...DGS1208SDZ EVAL ADGS1209SDZ User Guide UG 1271 Rev 0 Page 7 of 17 16732 005 Figure 5 ADGS1208 ADGS1209 Memory Map 16732 006 Figure 6 ADGS1208 ADGS1209 Memory Map with Unapplied Changes in the SW_DATA Register ...

Page 8: ...UG 1271 EVAL ADGS1208SDZ EVAL ADGS1209SDZ User Guide Rev 0 Page 8 of 17 EVALUATION BOARD SCHEMATICS AND ARTWORK EVAL ADGS1208SDZ 16732 007 Figure 7 EVAL ADGS1208SDZ Schematic 1 ...

Page 9: ...EVAL ADGS1208SDZ EVAL ADGS1209SDZ User Guide UG 1271 Rev 0 Page 9 of 17 16732 008 Figure 8 EVAL ADGS1208SDZ Schematic 2 ...

Page 10: ...UG 1271 EVAL ADGS1208SDZ EVAL ADGS1209SDZ User Guide Rev 0 Page 10 of 17 16732 009 Figure 9 EVAL ADGS1208SDZ Schematic 3 16732 010 Figure 10 EVAL ADGS1208SDZ Schematic 4 ...

Page 11: ...DGS1208SDZ EVAL ADGS1209SDZ User Guide UG 1271 Rev 0 Page 11 of 17 16732 011 Figure 11 EVAL ADGS1208SDZ Silk Screen 16732 012 Figure 12 EVAL ADGS1208SDZ Top Layer 16732 013 Figure 13 EVAL ADGS1208SDZ Layer 2 ...

Page 12: ...UG 1271 EVAL ADGS1208SDZ EVAL ADGS1209SDZ User Guide Rev 0 Page 12 of 17 16732 014 Figure 14 EVAL ADGS1208SDZ Layer 3 16732 015 Figure 15 EVAL ADGS1208SDZ Bottom Layer ...

Page 13: ...EVAL ADGS1208SDZ EVAL ADGS1209SDZ User Guide UG 1271 Rev 0 Page 13 of 17 EVAL ADGS1209SDZ 16732 016 Figure 16 EVAL ADGS1209SDZ Schematic 1 16732 017 Figure 17 EVAL ADGS1209SDZ Schematic 2 ...

Page 14: ...UG 1271 EVAL ADGS1208SDZ EVAL ADGS1209SDZ User Guide Rev 0 Page 14 of 17 16732 018 Figure 18 EVAL ADGS1209SDZ Schematic 3 16732 019 Figure 19 EVAL ADGS1209SDZ Schematic 4 ...

Page 15: ...DGS1208SDZ EVAL ADGS1209SDZ User Guide UG 1271 Rev 0 Page 15 of 17 16732 020 Figure 20 EVAL ADGS1209SDZ Silk Screen 16732 021 Figure 21 EVAL ADGS1209SDZ Top Layer 16732 022 Figure 22 EVAL ADGS1209SDZ Layer 2 ...

Page 16: ...UG 1271 EVAL ADGS1208SDZ EVAL ADGS1209SDZ User Guide Rev 0 Page 16 of 17 16732 023 Figure 23 EVAL ADGS1209SDZ Layer 3 16732 024 Figure 24 EVAL ADGS1209SDZ Bottom Layer ...

Page 17: ...cess the Evaluation Board As used herein the term Third Party includes any entity other than ADI Customer their employees affiliates and in house consultants The Evaluation Board is NOT sold to Customer all rights not expressly granted herein including ownership of the Evaluation Board are reserved by ADI CONFIDENTIALITY This Agreement and the Evaluation Board shall all be considered the confident...

Reviews: