EVAL-AD7175-8SDZ User Guide
UG-901
Rev. 0 | Page 3 of 10
QUICK START GUIDE
RECOMMENDED QUICK START GUIDE
Follow these steps to set up the board:
1.
Disconnect the SDP-B board from the USB port of the PC.
Install the
software from the enclosed CD.
Restart the PC after installation.
2.
Connect the SDP-B board to the
evaluation board, as shown in Figure 2.
3.
Fasten the two boards together with the enclosed plastic
screw washer set.
4.
Connect the external 9 V power supply to Connector J4
of the evaluation board, as shown in Figure 2. Set LK2 to
Position B.
5.
Connect the SDP-B board to the PC via the USB cable. For
Windows® XP, you may need to search for the SDP drivers.
Choose to automatically search for the drivers for the SDP-B
board if prompted by the operating system.
6.
From the
Analog Devices
subfolder in the
Programs
software.
QUICK START NOISE TEST
Use the following procedure to quickly test the noise
performance:
1.
Insert Link LK5 to Link LK20 to initiate the noise
performance test mode. In this mode, analog input
channels short to the REFOUT pin via SL11.
2.
In the evaluation software, click
Start Sampling
to acquire
samples from the ADC (see Figure 7).
The
Samples
numeric control in the top right corner of the
main window sets the number of samples collected in each
batch.
1
376
7-
00
2
Figure 2. Hardware Configuration, Setting Up the