UG-1268
User Guide
Rev. A | Page 6 of 22
7.
Double-click
EVAL-AD5758SDZ
to open the
block
diagram (see Figure 7). The
INITIAL CONFIGURATION
pane appears on the left side of the window. Several register
settings can be configured in this pane and are written to the
device in the appropriate order. The
DIG_DIAG_STATUS
,
RESET_OCCURED
, and
CAL_MEM_UNREFRESHED
LED indicators in the window are illuminated red by default.
Writing the initial configuration values clears these error
flags. If the device is power cycled, or if the USB cable is
disconnected and reconnected while the
software is
open, contact with the EVAL-AD5758SDZ can be lost. If
contact is lost, click the
System
tab, click the USB symbol
on the
EVAL-AD5758SDZ
, and then click
Acquire
to
communicate with the EVAL-AD5758SDZ.