2

dc1198bafa

DEMO MANUAL DC1198B-A

qUick stArt proceDUre

Figure 1. Test Setup of DC1198B-A

Demonstration circuit DC1198B-A is an easy way to evaluate 

the performance of the LTM4605EV. Please refer to Figure 

1 for proper measurement equipment set-up and follow 

the procedure below: 
1. Place jumpers in the following positions for a typical 

12V

OUT

 application:

RUN

CLOCK

MODE

START

ON

PROG

CCM

SSO

2. With power off, connect the input power supply, load 

and meters as shown in Figure 1. Preset the load to 0A 

and V

IN

 supply to be less than 20V. 

3. Turn on the power at the input. The output voltage 

should be 12V ± 2%.

4. Once the proper output voltage is established, adjust 

the load within the operating range and observe the 

output voltage regulation, ripple voltage, efficiency and 

other parameters. Cooling fan and lower current sensing 

resistor are necessary for V

IN

 < 5V and I

OUT

 = 5A.

5. To measure input and output ripple, please refer to 

Figure 2 for proper setup.

6. The voltage of pin PLLFLTR determines the switching 

frequency. Modify R6 and R7 to adjust the switching 

frequency. Turn off the power supply before attempting 

to remove and replace R6 and R7. Do not allow voltage 

at pin PLLFLTR exceed 2.4V.

7. The Inductor, RS1 and RS2 should be modified to ac-

commodate certain input and output condition. Please 

refer to the LTM4605 data sheet for recommended 

component values.

DC1198B F01