APPLICATION LAYER: COMMUNICATION PROTOCOL STATE MACHINE
Table 21. ADXL180 Start-Up Sequence Summary
Name
Phase 1
Initialization
Phase 2 Device Data
Phase 3 Self-Test
Phase 4 Auto-Zero
Initialization
Phase 5
Run Time
Function Power-on
reset
None
Sequence self-test
pattern
Fast auto-zero
Slow auto-
zero
Data Type
Transmitted
None
Serial number,
configuration and range
Sensor, range, device OK
or delimiter
Sensor Sensor
ADXL180 STATE MACHINE
After power is applied and stabilized, the ADXL180 follows a
five-phase start-up sequence. The basic function of each phase
is fixed as shown in Figure 20. The five phases and the function
modes available in each phase are detailed in the following
sections.
V
DD
> V
PUR
RESET
PHASE 1 INITIALIZATION
PHASE 2
DEVICE DATA
PHASE 3
SELF-TEST
PHASE 5
NORMAL OPERATION
RESET
ERROR STATE
TRANSMIT ERROR CODE
PHASE 4
AUTO-ZERO INITIALIZATION
RESET
RESET
RESET
RESET
ERROR
ERROR
ERROR
ERROR
RESET
07
54
4-
03
9
Figure 20. ADXL180 Start-Up Sequence
PHASE 1: POWER-ON-RESET INITIALIZATION
The power-on-reset initialization period is typically 100 ms
long. It is the period of time from when the internal reset signal
is deasserted until the beginning of Phase 2. This time allows
for circuit stabilization and entry into configuration mode. No
data is transmitted during Phase 1. No errors are reported
during Phase 1. Additionally, until phase 1 is exited, the device
does not respond to a transmitted sync pulse (see Table 21).
PHASE 2: DEVICE DATA TRANSMISSION
Overview
The device data consists of the serial number and configuration
data. Device data is transmitted during Phase 2. This data can
be transmitted in one of four configurable modes (see Table 22).
These modes are described in detail in the following sections.
The parity of all OTP memory blocks is continuously monitored
(provided that the block has been programmed) beginning at
the end of Phase 2. See the Parity Encoding section for more
details.
Table 22. MD Phase 2 Device Data Mode Select Codes
MD1 MD0 Name Definition
0
0
Mode 0
ADIFX mode device data (default)
0 1 Mode
1
Range data only (range selection
limited)
1
0
Mode 2
8-bit coded device data
1
1
Mode 3
10-bit coded device data
During Phase 2, if Mode 0, Mode 1, or Mode 2 is selected, the
device data is 8-bit data. If the 10-bit data mode is selected in
combination with Phase 2 Mode 0, Mode 1, or Mode 2, the 8-bit
device data is left justified in the 10-bit data field. The two LSBs
are held at zero (see Table 24).