background image

UG-880 

ADP5302-EVALZ User Guide 

 

Rev. 0 | Page 4 of 7 

MEASURING EVALUATION BOARD PERFORMANCE 

Measuring the Switching Waveform 

To observe the switching waveform with an oscilloscope, place 
the oscilloscope probe tip at the TP2 and TP5 test points with the 
probe ground connected to GND. Set the oscilloscope to a dc 
coupling, 2 V/division, 1 µs/division time base. The switching 
waveform alternates between 0 V and the approximate input 
voltage. 

Measuring Load Regulation 

Test load regulation by increasing the load at the output and 
measuring the output voltage between the TP4 and TP7 test 

points. 

Measuring Line Regulation 

Vary the input voltage and measure the output voltage at a fixed 
output current. The input voltage can be measured between the 
TP1 and TP5 test points. The output voltage is measured 

between the TP4 and TP7 test points. 

Measuring Efficiency 

The efficiency, η, is measured by comparing the input power 
with the output power. 

IN

IN

OUT

OUT

I

V

I

V

η

×

×

=

 

Measuring Inductor Current 

Measure the inductor current by removing one end of the 
inductor from the pad on the board and using a wire connected 
between the pad and the inductor. A current probe can then be 

used to measure the inductor current. 

Measuring Output Voltage Ripple 

To observe the output voltage ripple, place an oscilloscope 
probe across Output Capacitors C1, C8, and C10 with the probe 
ground lead placed at the negative capacitor terminal (−) and 
the probe tip placed at the positive capacitor terminal (+). Set 

the oscilloscope to an ac coupling, 10 mV/division, 

2 µs/division time base and 20 MHz bandwidth. 
A standard oscilloscope probe has a long wire ground clip. For 
high frequency measurements, this ground clip picks up high 

frequency noise and injects it into the measured output ripple. 
Figure 2 shows a simple way to properly measure the output 
ripple. It requires removing the oscilloscope probe sheath and 
wrapping a nonshielded wire around the oscilloscope probe.  
By keeping the ground lengths of the oscilloscope probe as 

short as possible, true ripple can be measured. 

 

Figure 2. Output Ripple Measurement 

Output Voltage Change 

The output voltage of the evaluation board is preset to 1.8 V. 
However, the output voltage can be adjusted with an external 

VID resistor (see the 

ADP5302

 data sheet). 

 
 
 

 