There are two types of installations for the N-Series Wall Controllers: Ring 

Adapter (when mounting into an existing electrical box) and Flushmount (when 

mounting into an SVSI-provided installation box). 

Note: If desired, you can pre-configure the unit before physically installing it. To 

do so, simply plug a PoE (Power over Ethernet) enabled Ethernet connection into 

the back of the controller and skip to the section Configuring Your New Wall Con-

troller for further instructions.

Important: For ease of installation, only use bootless Ethernet cables when 

installing the Controller into the wall. The flexibility is necessary for proper 

positioning in the box’s small space.

Mounting Instructions - Ring Adapter Installation

Follow the steps below to mount your new SC-WPC-SM/SC-TC-SM into an 

existing dual gang electrical box. The instructions given assume the box is 

already installed with Ethernet access running to it.

1. Secure the mounting ring adapter (included in shipment) to your existing 

dual gang electrical box with four screws.

2. Connect the PoE-enabled Ethernet cable to the rear connector of the wall 

controller. 

3. Place the wall controller display into the box and secure it with four screws 

(included in shipment).

4. Complete the installation by snapping the AMX faceplate onto the front.

Ring Adapter Installation (SC-WPC-SM/SC-TC-SM)

QUICK START GUIDE

SVSI SC-WPC:  Stand-alone, dual-gang IP wall controller (push-button)

SVSI SC-TC: 

Stand-alone, dual-gang IP wall controller (push-button 

and touchscreen with built-in WiFi)

N-Series Wall Controllers

1. Using the 

Wall Controller Installation Cut-Out Template

 (enclosed in ship-

ment), mark the position on the wall where the unit is being installed and cut 

the opening.

2. Once the opening is cut (and the PoE-enabled Ethernet cable is accessible 

through the opening) insert the plastic installation box (included in 

shipment). Use the break-out tabs as needed to correctly position the 

Ethernet cable.

3. Secure the installation box to the wall with the two captive screws.

4. Connect the Ethernet cable to the rear connector of the wall controller.

5. Place the wall controller display into the box and secure it with four screws 

(included in shipment).

6. Complete the installation by snapping the AMX faceplate onto the front of the 

Flushmount Installation (SC-WPC-D/SC-TC-D)

Mounting Instructions - Flushmount Installation

Follow these steps to flushmount your new SC-WPC-D/SC-TC-D into the wall. 

The steps given assume the installer needs no instruction on running Ethernet 

to the installation box or other basics.

Configuring Your New Wall Controller

You will not be able to configure the controller until it is in the same subnet as 

the host PC. N-Touch devices are shipped in Auto-IP mode with a default IP 

address of 169.254.xxx.xxx. Before attempting configuration, some changes 

must be made to the host PC.

Sample steps for IP address configuration (Windows):

1. From the 

Control Panel > Network and Internet 

dialog box, select 

Network 

and Sharing Center

.

2. Select 

Change adapter settings

.

3. Select the wired interface connected to your AV network.

(Continued)

1. Using the 

Wall Controller Installation Cut-Out Template

 (enclosed in ship-

ment), mark the position on the wall where the unit is being installed and cut 

the opening.

2. Once the opening is cut (and the PoE-enabled Ethernet cable is accessible 

through the opening) insert the plastic installation box (included in 

shipment). Use the break-out tabs as needed to correctly position the 

Ethernet cable.

3. Secure the installation box to the wall with the two captive screws.

4. Connect the Ethernet cable to the rear connector of the wall controller.

5. Place the wall controller display into the box and secure it with four screws 

(included in shipment).

6. Complete the installation by snapping the AMX faceplate onto the front of the 

wall controller.

Configuring Your New Wall Controller (Continued)

4.Click the 

Properties

 button.

5.Scroll down in the list to the 

Internet Protocol Version 4 

(TCP/IPv4)

 option. Highlight it 

and click the 

Properties

 

button.The screen shown (at 

left) is displayed.

6.Enable the 

Use the following 

IP address

 option, and enter the 

static IP address

 

provided to you 

by your network administrator.

Logging in for the 

First Time

Once connected to the network, 

the welcome screen appears on 

the N-Series Wall Controller’s 

front panel and displays the unit’s serial number, MAC address, and IP address. 

1. Using your computer, enter the N-Series Wall Controller’s IP address into your 

web browser.

2. The 

N-Series Wall Panel Controller Login

 screen displays. Use the default 

login credentials (username = 

admin

/password = 

password

)

 

to log in for the 

first time. Upon successful login, the 

Settings

 page displays (shown at right).

See the section 

Using 

Panel Builder

 for details.

Click 

Settings

 to 

return to this screen.

Click 

to access 

additional 

documentation.

See the section 

Viewing 

Panels on the SVSI 

Conductor Mobile App

 for 

details on the 

Users 

screen.

See the section 

Wireless 

Configuration (SC-TC 

Units Only)

 for details.

Reviews: