 REV: C

Last Revised: 12/01/2017

NOTE: When in ID Mode, the entire system is put on hold while it waits for an event 

from any NetLinx device in the named system (e.g., pressing the ID Pushbutton on 

the switcher). The device that generates the first event is the device that will be 

“identified.”

6.

Briefly press and release the ID Pushbutton on the switcher. The switcher will 

exhibit the following behavior:

• Respond with an ID Mode address response.
• Report its old address offline.
• Report its new address online.

The Online Tree will refresh to display the new device address for the switcher.

NOTE: NetLinx Studio (v3.3 or later) provides the ability to auto-increment IP 

Addresses and Hostnames as well as Device and System Numbers. Refer to the 

NetLinx Studio online help for details.

Restore the Factory Firmware Image and Factory Default Parameters

During power up

 – if you hold the ID Pushbutton until the STATUS and 

LINK/ACT LEDs toggle back and forth in unison approximately 30 times (10 slow,

20 fast) and then release the pushbutton when the LEDs turn solid, the switcher’s

factory firmware image will be restored. This procedure affects both the firmware

version and the parameters.
Perform these steps to restore the factory firmware image and factory default

parameters:
1.

Press and hold the ID Pushbutton while plugging in the power connector. 

Start counting when the STATUS and LINK/ACT LEDs begin to flash in unison, 

not when the power connector is inserted.

2.

After the LEDs complete the following sequence, release the ID Pushbutton:

• Once the switcher has started booting up, all LEDs flash in unison at the rate

of once per second.

• After 10 flashes at that rate, the LEDs will blink in unison at a faster rate.
• After 10 seconds of flashing at the increased rate, all LEDs turn on solid.

3.

Upon release of the ID Pushbutton, the switcher executes the following 

actions:

• Restores itself to its factory firmware image.
• Resets to factory default parameters

4.

Once all actions in Step 3 are completed, the LEDs all turn off, indicating the 

switcher is ready to reboot.

The switcher automatically reboots to complete the process.

Hardware Information

This section lists important hardware information for the SDX-414-DX.

Port Numbers

Default IP Addresses

The default IP addressing mode is DHCP.

Important Twisted Pair Cabling Requirements and Recommendations

The following requirements and recommendations apply to cabling DXLink

(RJ-45) connectors:

• DXLink cable runs require shielded category cable (STP) of Cat6 (or better).
• DXLink twisted pair cable runs for DXLink equipment shall only be run within

a common building.*

• DXLink delivers 10.2 Gb/s throughput over shielded category cable. Based

on this bandwidth requirement, we recommend following industry standard

practices designed for 10 Gigabit Ethernet when designing and installing

the cable infrastructure.

• The cables should be no longer than necessary to reach the endpoints. We

recommend terminating the cable to the actual distance required rather

than leaving any excess cable in a service loop.

For more details and helpful cabling information, reference the white paper titled

"Cabling for Success with DXLink" available at www.amx.com or contact your

AMX representative.
* "Common building" is defined as: Where the walls of the structure(s) are

physically connected and the structure(s) share a single ground reference.

Additional Documentation

Additional documentation for this device is available at 

www.amx.com

. Refer to

the 

Solecis SDX Digital Switchers Instruction Manual

 for additional details on

installing, upgrading, and wiring the SDX-414-DX.
You can also access this Quick Start Guide online by using your mobile device to

scan the QR code located on the bottom of the SDX-414-DX.

SDX-414-DX PORT NUMBERS

Port

Port Number

Address

HDMI IN 1

1

<DevID>:1:0

HDMI IN 2

2

<DevID>:2:0

HDMI IN 3

3

<DevID>:3:0

HDMI IN 4

4

<DevID>:4:0

HDMI OUT

1

<DevID>:1:0

DXLINK OUT

1

<DevID>:1:0

External Buttons

14

<DevID>:14:0

AXLINK Keypad 1

15

<DevID>:15:0

AXLINK Keypad 2

17

<DevID>:17:0

SDX-414-DX DEFAULT IP ADDRESSES

Static IP Address

192.168.1.2

Link-Local Address

169.254.2.2