Installation Sheet

RDD-DM4

 4-Channel Integrated Dimmer Module 120,240,277 VAC

The RDD-DM4 Four-Channel Integrated Dimmer Module controls up to six 
dimmed channels with four 1200 W onboard dimmers and two satellite 
connectors (for RDM series dimmer or switching modules). It is designed 
for use with the RDA series of enclosures, in an AMX Lighting™ modular 
digital dimming system. The RDD-DM4 is controlled by AXlink, PROlink, or 
by dry (contact) closures. The RDD-DM4’s 120, 240, or 277 VAC ratings are 
CE, UL, and C-UL approved.

RDD-DM4 UL and C-UL Ratings: (per circuit)

Input

120, 240, 277 VAC, single phase, 3-wire, 50/60 Hz, 2400 W, one feed

120 ,240, 277 VAC, single phase, 4-wire, 50/60 Hz, 4800 W, dual feed

Output

1200 W max. per channel @120, 240, 277 VAC

2400 W max. total, all four channels on with 2400 W feed

4800 W max. total, all four channels on with dual 2400 W feeds

Feed circuit #1 goes to dimmer 1 and 3; feed circuit #2 goes to dimmer 

2 and 4.

Specifications

Dimensions (HW): 5.87" x 10.0" (149.00 mm x 254.00 mm)

Use wires rated at 75°C (167°F)

Torque terminals to 20 in-lbs (2.3 N/M)

Max. wire size: 10 AWG (4 mm²)

Wire stripping length: 0.35" (9 mm)

Weight: 4.5 lbs (2.04 kg)

BTU/hr: 300 single feed (2400 W); 600 dual feed (4800 W)

Power consumption: 50 mA @ 120 VAC, 25 mA @ 240 VAC, 22 mA 

@ 277 VAC

Control port current: 200 mA @ 12 VDC

Loads: 

Button/Jumper Information:

RESET button:  By pressing the RESET button, located on the 

RDD-DM4 circuit board, it is possible to restart the processor without 
having to power-down the unit or disconnect AXlink or PROlink. 
RESET does not affect any saved presets or curve settings.

MEMORY PROTECT on/off jumper:  The MEMORY PROTECT 

jumper is set to Off by default. When put in the On position, saved 
curve settings and presets are protected in case of a power failure.

Caution: Pre-Installation Notes

All Class 1 wiring must be connected to proper terminals.

All control wiring must be connected to proper terminals.

Disconnect power while installing or connecting the unit.

Keep top and bottom air vents clear at all times.

Test loads for shorts before connecting.

Use low-voltage wires with a 300 volt rating or greater.

Use field-installed copper conductors.

All electrical ratings are for continuous duty.

For indoor use only.

AC lighting loads only.

This module may require extra power from the AXlink connection or an 

external power supply connected to the control card.

Connecting the RDD-DM4 to the AMX Lighting Master   

Connecting AXlink:

Connect the 4-pin captive-wire AXlink from the RDD-DM4 to the Central 
Controller for AXlink control of the dimming system.    

  

 

Connecting PROlink:

Connect the orange 4-pin captive-wire PROlink connector from the 
RDD-DM4 to a PRO-DP8 PROlink wall panel.  

  

FIG. 1  

RDD-DM4 4-channel Integrated Dimmer Module

Mounting
points

Power
device

Bridge
Line In

High-voltage
connections

Load out

AXlink

 

address

DIP switch

PROlink

    address
DIP

 

switch

Low-voltage
control

 

wiring: 4-pin
connectors
to RDM
series modules

PROlink

External
+12 V
power
connector
(optional)

Memory
Protect
jumper

Reset
button

Chokes

Neutral

AXlink
connector

Dry Closures

Suggested Loads

Dimmed

Switched (at 600 W)

Incandescent

Fans

Low-voltage

Florescent ballast

Neon, cold-cathode

Motors

FIG. 2  

RDD-DM4 connections

FIG. 3  

Connecting AXlink

FIG. 4  

Connecting PROlink

Pin 4 (GND)

Pin 3 (RLY)
Pin 2 (DIM)

Pin 1 (+12 V)

3 (-)

1 (+)

RDD-DM4 4-pin module connector

4-pin plug from RDM series module

NOTE: The 4-pin plugs from the module connector to
the 4-pin connector on the master (black plug cover facing up).

PWR

AXP

AXM

GND

PWR
AXP

AXM

GND

Central 

RDD-DM4

Controller

(optional)

PRO-DP8

Pack 1

Pack 2

+12

PR+

PR-

GND

+12

PR+

PR-

GND

Reviews: