To avoid damaging the PMB-TCC when connecting to external volt-
age-sensing applications, it must be connected as shown in FIG. 3.

4.

If you are connecting a powered external device that will run on 
12VDC (max. 700mA), connect the +12VDC lead and the GND lead 
to the corresponding pins on the four-pin female Phoenix connector 
(see previous step) and plug it into the Contact Phoenix connector on 
the rear panel of the PMB-TCC.

5.

If you are using an optional Xantech external IR receiver instead of 
the built-in IR receiver (this disables the built-in IR receiver), connect 
the Xantech receiver as follows:

Cut off the plug that came with the Xantech IR receiver and strip 

about 1/4 inch of insulation from the ends of the wire.

The receiver has three leads: Ground, +12V, and Output. The lead 

with the white or red stripe is Output (signal), the middle lead is +12V, 
and the third lead is Ground. Connect these leads to the correspond-
ing terminals on a three-pin female Phoenix connector and plug the 
connector into the IR Phoenix connector on the rear panel.

6.

Insert the 12VDC power supply plug into the DC 12V receptacle on 
the rear panel.

7.

Plug the power supply into a properly grounded 120VAC outlet. The 
Power LED on the front panel should be illuminated.

8.

With the Landmark Designer software in Identify mode, press the ID 
button on the front panel four times to send device ID information to 
the Landmark system. This allows you to make the correct software 
connection to this physical device.

The Link LED flashes when data is sent from the contact box regard-

ing a change of a relay state, when a command to get the state of the 
relays is sent to the box from the Landmark system, and when an ID 
signal is sent to the box from the Landmark system. The IR In and IR 
Out LEDs flash whenever an IR command is received or sent.

Troubleshooting

If you are having difficulty receiving commands, check the following:

Make sure there is only one IR receiver per room, and that the IR 

receiver in each room is not positioned so that it can receive signals 
from a nearby room, or external sources of IR, such as the sun or 
excessively bright fluorescent lighting. These include the PMB-IRI, 
PMB-TCC, or the PLC-IRIN and any connected IR receivers.

Make sure none of the IR receivers are placed in locations that 

receive direct or high levels of sunlight. Reposition if necessary.

Start Landmark Designer and monitor the PMB-TCC function in the 

Network Log. Make a number of clean button-press commands. You 
should see these come in on the correct port. Watch for any interfer-
ence from other ports.

Check the remote mode when comparing programming functions. 

Make sure the mode matches the appropriate programming mode.

FIG. 3  Connecting to an external device to sense 5VDC or 12VDC.

Contact 1

GND

R

+12VDC or +5VDC
(output from 

1/4-watt resistors

GND
(GND side of 

 external device)

 external device*)

2

 

 

Voltage

+5

+12

* When connecting a 
grounded device, make 
sure the ground potential is 
the same as the PHAST 
TCC ground.

R

1KW

1KW

R

2.2KW

560W

1

2