P C S 2
D ATA S H E E T
3000 RESEARCH DRIVE, RICHARDSON, TX 75082 • 800.222.0193 • 469.624.8000 • +1.469.624.7400 • 469.624.7153 fax • www.amx.com
PCS2 (FG427)
POWER
110 VAC @ 250 mA minimum
ENCLOSURE
•
Metal with black matte finish
•
Mounts in optional AC-RK Accessory Rack Kit
DIMENSIONS (HWD)
1 1/2” x 5 1/2” x 5 1/2” (38 mm x 140 mm x 140 mm)
SENSING
•
Standby:
•
On:
•
Sense Levels:
CONNECTIONS
•
On 1, 2:
•
Stby 1, 2:
•
Com 1, 2:
•
AC 1, 2:
•
AC Power:
INCLUDES
6-pin captive-screw terminal
WEIGHT
28.8 oz (816 g)
C
O
M
1
O
N
S
T
B
Y
C
O
M
AC 1
2
O
N
S
T
B
Y
AC 2
CLASS 2 CIRCUIT ONLY
Power Current Sensor
POWER
PCS2
COMBINED OUTPUT 120 VAC 1200W 50/60 Hz
STANDBY
ON
AC 1
120 VAC
50/60 Hz
10 AMP
STANDBY
ON
AC 2
PCS2 (Top View)
PCS2 (Front Side)
PCS2 (Rear Side)
5 1/2” (140 mm)
5 1/2 “
(140 mm)
1 1/2 “
(38 mm)
AV
Receiver
PCS2
NetLinx I/O Ports
or
Television Controllers
or
Other
Closure-Controlled
Devices
Device
(TV)
AC Power
Input
Relay
Output
I/O
Input
AC Power
Output 1
AC Power
Output 2
EXAMPLE SYSTEM
On sense relay output, 1 A @ 28 VDC
Standby sense relay output, 1 A @ 28 VDC
Common for sense outputs
Two US style 3-prong 110 VAC receptacles
1,200 W (10A) output power, fuse protected
US style 3-prong 110 VAC power cord
Two Standby status LEDs
Two Standby sense adjustment screws
Two On status LEDs
Two On sense adjustment screws
20 mA–10 A power current