AMX PCS2 Datasheet Download Page 2

P C S 2  

D ATA   S H E E T

3000 RESEARCH DRIVE, RICHARDSON, TX 75082  •  800.222.0193  •  469.624.8000  •  +1.469.624.7400  •  469.624.7153 fax  •  www.amx.com

PCS2 (FG427)

POWER

110 VAC @ 250 mA minimum

ENCLOSURE

 Metal with black matte finish

 Mounts in optional AC-RK Accessory Rack Kit

DIMENSIONS (HWD)

1 1/2” x 5 1/2” x 5 1/2” (38 mm x 140 mm x 140 mm)

SENSING

 Standby: 

 On: 

 Sense Levels: 

CONNECTIONS

 On 1, 2: 

 Stby 1, 2:  

 Com 1, 2:  

 AC 1, 2: 

 AC Power: 

INCLUDES

6-pin captive-screw terminal

WEIGHT

28.8 oz (816 g)

C

O

M

1

O

N

S

T

B

Y

C

O

M

AC 1

2

O

N

S

T

B

Y

AC 2

CLASS 2 CIRCUIT ONLY

Power Current Sensor

POWER

PCS2

COMBINED OUTPUT 120 VAC 1200W  50/60 Hz

STANDBY

ON

AC 1

120 VAC

50/60 Hz

10 AMP

STANDBY

ON

AC 2

PCS2 (Top View)

PCS2 (Front Side)

PCS2 (Rear Side)

5 1/2” (140 mm)

5 1/2 “ 

(140 mm)

1 1/2 “ 

(38 mm)

AV

Receiver

PCS2

NetLinx I/O Ports

or

Television Controllers

or

Other 

Closure-Controlled

Devices

Device

(TV)

AC Power
Input

Relay
Output

I/O

Input

AC Power

Output 1

AC Power

Output 2

EXAMPLE SYSTEM 

On sense relay output, 1 A @ 28 VDC
Standby sense relay output, 1 A @ 28 VDC
Common for sense outputs
Two US style 3-prong 110 VAC receptacles
1,200 W (10A) output power, fuse protected
US style 3-prong 110 VAC power cord

Two Standby status LEDs
Two Standby sense adjustment screws
Two On status LEDs
Two On sense adjustment screws
20 mA–10 A power current

Reviews: