background image

For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).

11/11

©2011 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX.

AMX reserves the right to alter specifications without notice at any time. 

3000 RESEARCH DRIVE, RICHARDSON, TX 75082 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993 • www.amx.com

    93-2262-01

 

REV: D 

Installation of the NXD-430

While the NXD-430 is designed to fit into pre-existing NXD-CV5 touch panel sites, 
the actual installation differs from that of the NXD-CV5 in several significant ways. 
The NXD-430 can be installed either directly into the (optional) CB-TP5I Rough-In 
Box or another solid surface environment, using either solid surface screws or the 
included locking tabs for different mounting options. For more information, please 
refer to the 

NXD-430/435 Operation/Reference Guide

, available at 

www.amx.com

.

The NXD-430 is contained within a clear outer housing known as the back box 
(FIG. 3). This back box is not removed when installing the device into a wall or into a 

Rough-In Box. 

Installing the NXD-430 into a wall

Unlike most AMX touchpanels, the NXD-430 comes with a clear plastic backbox 
(FIG. 7) designed to attach the panel to most standard wall materials. This backbox 
has a locking tab on three of the four faces (missing only on the face containing the 
space for the connections) to help lock the backbox to the wall. These locking tabs 
are only extended AFTER the backbox is inserted into the wall.

WARNING:

 When installing the backbox, make sure that the assembly is in the 

correct position and in the correct place. Once the locking tabs are extended and 
locked into place, removing the backbox may be difficult without having access to the 
back of the wall or causing damage to the wall. 

Note: 

In order to guarantee a stable installation of the NXD-430, the thickness of the 

wall material must be a minimum of .50 inches (1.27cm) and a maximum of .875 
inches (2.22cm).

WARNING:

 The maximum recommended torque to screw in the locking tabs on the 

plastic back box is 5 IN-LB [56 N-CM]. Applying excessive torque while tightening the 
tab screws, such as with powered screwdrivers, can strip out the locking tabs or 
damage the plastic back box.

1.

Prepare the area by removing any screws or nails from the drywall before 
beginning the cutout process.

2.

Cut out the surface for the back box. Refer to the dimensions in the 

NXD-430/

435 Operation/Reference Guide

, available from 

www.amx.com

, for more 

information.

CAUTION:

 Making sure that the actual cutout opening be slightly smaller than the 

provided dimensions is highly recommended. This action provides the installer with a 
margin for error if the opening needs to be expanded. Too little wall material removed 
is always better than too much.

3.

Remove the faceplate from the NXD-430.

4.

Disconnect the capacitive touch connector from the 10-pin plug on the 

faceplate.

5.

Insert both connectors into their corresponding locations along the left side of 
the NXD-430 touch panel.

6.

Test the incoming wiring by attaching the panel connections to their terminal 
locations and applying power via the PoE Injector. Verify that the panel is 
receiving power and functioning properly to prevent repetition of the 
installation.

7.

Thread the incoming Ethernet and mini-USB wiring (if mini-USB access is 
desired) from their terminal locations through the surface opening. 

Leave 

enough slack in the wiring to accommodate any re-positioning of the panel.

8.

Push the back box into the wall opening. Insure that the locking tabs lie flush 
against the back box.

9.

Extend the locking tabs on the sides of the back box by tightening the screws 
inside the box until snug. Not all of the tabs must be extended to lock the back 
box in place, but extending a minimum of the top and bottom tabs is highly 
recommended. Apply enough pressure to the screw head to keep the box flush 
with the wall: this ensures that the locking tabs will tighten up against the inside 
of the wall. 

The back box is clear to allow visual confirmation that the tabs have been 
extended and are gripping the wall, as well as in assisting with removal if 
necessary.

NOTE:

 Do not disconnect the connectors from the touch panel. The unit must be 

installed with the attached connectors before being inserted into the drywall.

10.

Carefully replace the two Plastite screws holding the device to the back box.

11.

Reconnect the capacitive touch connector to the 10-pin plug on the faceplate.

12.

Place the faceplate back onto the device.

13.

Reconnect the terminal Ethernet and USB to their respective locations on 
either the Ethernet port or NetLinx Master.

Installing the NXD-430 into a Flat Surface using #4 screws

Three #4 mounting screws (not included) are secured through circular holes located 
at the left and right sides of the NXD-430. The most important thing to remember 
when mounting the NXD-430 is that the outer frame (Mounting Tabs) must be 
installed flush against the mounting surface.

Refer to SP-2262-02 for detailed installation dimensions.

Cutting out the surface slightly smaller than what is outlined in the installation 

drawings in order to make any necessary cutout adjustments, is highly 
recommended.

1.

Prepare the area by removing any screws or nails from the surface before 
beginning the cutout process.

2.

Cut out the surface for the NXD-430.

3.

Remove the faceplate from the NXD-430.

4.

Disconnect the capacitive touch connector from the 10-pin plug on the 

faceplate.

5.

Thread the incoming Ethernet and USB wiring from their terminal sources 
through the surface opening. Leave enough slack in the wiring to 
accommodate any re-positioning of the panel.

6.

Connect the Ethernet and USB connectors to their corresponding locations 
along the left side of the un-powered NXD-430 touch panel. The USB 
connectors can be from either a USB extension cable or a wireless USB RF 
transmitter.

NOTE: 

Do not disconnect the connectors from the touch panel. The unit must be 

installed with the necessary connectors before being inserted into the solid surface. 

7.

Carefully slide the main unit into the cutout until the Mounting Tabs of the 
NXD-430 lie flush against the wall.

8.

Insert and secure three #4 Mounting Screws (not included) into the 
corresponding holes located along the sides of the NXD-430, using a grounded 
Phillips-head screwdriver, until the unit is secure and flush against the wall.

9.

Reconnect the capacitive touch connector to the 10-pin plug on the faceplate.

10.

Place the faceplate back onto the device.

11.

Reconnect the terminal Ethernet and USB to their respective locations on 
either the Ethernet port or NetLinx Master.

FIG. 3  

NXD-430 backbox with closed and open locking tabs

Locking tabs - Closed

Locking tabs - Open

Locking tab screws