background image

Installation Guide

NXD-430 

4.3" Modero

®

 Wall/Flush Mount Touch Panel

For more detailed installation, configuration, programming, file transfer, and operating 
instructions, refer to the 

NXD-430/435 Operation/Reference Guide

, available online at 

www.amx.com

.   

Overview

The NXD-430 Modero

®

 Wall/Flush Mount Touch Panel includes a mini-USB port for 

programming and one NetLinx-programmable button. All power is supplied via Power 
Over Ethernet (PoE), utilizing a PS-POE-AF PoE Injector (

FG423-80

) or equivalent 

PoE device.The NXD-430 comes in black (

FG2262-01

) and white (

FG2262-02

).

Specifications     

Panel Connectors and Wiring

FIG. 2 shows the connectors located on the NXD-430 Modero panel. The mini-USB 
port is used for programming the touch panel. 

For more information on connection and use of the Panel Connectors, as well as 
information on programming, please refer to the 

NXD-430/435 Operation/Reference 

Guide

, available at 

www.amx.com

.

Capacitive Touch Button

The NXD-430 has one main button on the front of the device, in the center of the 
bezel. This button has several uses:

Press the button once to start a previously programmed function, or to turn off 

the display if not previously programmed.

Press and hold the button for 6 seconds to put the device into 

Setup Mode

.

Press and hold the button for 9 seconds to enter 

Calibration Mode

.

Press and hold the button for 20 seconds to reboot the panel.

The front button of the NXD-430 utilizes capacitive touch, which detects the electrical 
conductivity of human skin and reacts directly to touch. This allows the button to resist 
wear and dirt, as the button does not have any actual physical button to depress.

NXD-430 Setup and System Connection

1.

Carefully remove the panel from the shipping box, peel the protective plastic 
cover from the LCD, and apply power to the panel via the PoE Injector.

2.

From below the LCD, press the front button for 9 seconds (passing over the 

Setup

 page) to access the 

Calibration

 setup page and follow the on-screen 

instructions to return to the main 

Setup

 page.

3.

Press the on-screen 

Protected Setup

 button on the 

Setup

 page.

4.

Enter the panel password into the on-screen keypad (default is 

1988)

.

5.

Press the 

Device Number

 field to open the on-screen Device Number keypad 

and enter a value for the panel (

default is 32001

).

6.

Press the 

System Settings

 button to open the 

System Settings

 page.

7.

From the 

IP

 tab, toggle the 

DHCP Static 

field to 

DHCP

 if it is not already set to 

DHCP.

8.

From the 

Master

 tab, toggle the 

Type

 field to 

Ethernet

.

Toggle the 

Mode

 field to 

URL

.

Enter both the System Number and IP Address of the target Master.

9.

Enter a valid Username and Password if the target Master is secured.

10.

Press the 

Back

 button and then press the on-screen 

Reboot

 button to save any 

changes and cycle power to the panel.

FIG. 1  

NXD-430 4.3" Modero Wall/Flush Mount Touch Panel - White

NXD-430 (FG2262-01/02) Specifications

Dimensions (HWD):

• NXD-430: 4.13" x 5.5” x 2.13" (10.48 cm x 13.97 cm x 5.40 cm)
• CB-TP5 Rough-In/Wallbox (optional): 4.27" x 5.14" x 3.40" 

(10.86 cm x 13.06 cm x 8.64 cm)

Weight:

• 0.65 lbs (0.29 kg)

Power 

Requirements:

• PoE Powered - No local Power Supply needed
• Max power draw: 5.5W.

Memory (Factory 
default):

• 128 MB SDRAM 
• 256 MB integrated Flash Memory (not upgradeable - factory 

programmed)

Certifications:

• FCC Part 15 Class B
• CE
• IEC 60950
• RoHS

Panel LCD 

 Parameters:

• Aspect ratio: 16 x 9
• Minimum brightness (luminance): 280 cd/m2
• Channel transparency: 8-bit Alpha blending 
• Contrast ratio: 250:1
• Display colors: 256 thousand colors (18-bit color depth)
• Dot/pixel pitch: 0.14 mm
• Panel type: WQVGA
• Screen resolution: 480 x 272 pixels (HV) @ 60 Hz frame 

frequency

• Viewing dimensions: 2 3/16" x 3 13/16" (5.56 cm x 9.68 cm)

Active Screen Area:

• 2 1/8" x 3 3/4" (5.40 cm x 9.53 cm)

Viewing Angles:

• Left/Right/Up/Down: 80/80/60/80

Front Panel 

Components:

Center Button:

 Capacitive touch button provides both access to 

the 

Setup

 and 

Calibration

 pages and toggles the panel between 

a "sleep" or "wake" state. This button is also user-
programmable.

Side Panel 

 Connectors:

• Ethernet 10/100 Port:: RJ-45 port for 10/100 Mbps 

communication. The Ethernet port automatically negotiates the 
connection speed (10 Mbps or 100 Mbps), and whether to use 
half duplex or full duplex mode. Power is supplied through 
Power Over Internet (PoE). NXD-430 panels communicate with 
the NetLinx Master using the ICSP protocol over Ethernet. LEDs 
show communication activity, connections, speeds, and mode 
information:

L/A-link/activity

 - Yellow LED lights On when the Ethernet cables 

are connected and terminated correctly and then blinks when 
receiving Ethernet data packets.

SPD-speed

 - Green LED lights On when the connection speed is 

100 Mbps and turns Off when the speed is 10 Mbps.

• Mini-USB Connector: 5-pin Mini-USB connector used for 

programming, firmware update, and touch panel file transfer 
between the PC and the target panel.

Capacitive Touch Center Button

Touch screen

NXD-430 Specifications (Cont.)

Operating /Storage

 Environments:

• Operating Temperature: 0° C (32° F) to 40° C (104° F)
• Operating Humidity: 5% - 85% relative humidity 

(non-condensing)

• Storage Temperature: -20° C (-4° F) to 60° C (140° F)
• Storage Humidity: 5% - 85% RH

Included 

Accessories:

• NXD-430 Installation Guide (

93-2262-01

)

Other AMX 

 Equipment:

• CB-TP5i Rough-In/Wallbox (

FG038-11

)

• Back Cover for the CB-TP5i Rough-In/Wallbox (

FG038-12

)

• PS-POE-AF PoE Injector (

FG423-80

)

• NXA-BEZP-430-BK Black Portrait Bezel Kit for the NXD-430 

(

FG2262-10

)

• NXA-BEZP-430-WH White Portrait Bezel Kit for the NXD-430 

(

FG2262-11

)

• CC-USB Type-A to Mini-B 5-wire programming cable 

(

FG10-5965

)

• NXA-RK5 Rack Mount Kit for 5" Wall Mount panels (

FG2904-55

):

- 5" Rackmount 

- Four Screws, #10-32 x.625, PH Truss, BLK 

- Four Washers, #10, Black Nylon

- Three Screws, #4-40 x.250, PPH, BLK 

FIG. 2  

Connector layout on the NXD-430 Modero Wall/Flush Touch Panel

Ethernet 10/100 port

Mini-USB port

Back box

Reviews: