Step 3: Modify the Source Code on your Master

Before you can use either the Computer Control or TakeNote applications, you 
must first modify the NetLinx Master Source Code to support the new (G4CC) 
functionality:
1.

Insert the NXA-USBTN stick into a USB port on the PC that is being 

 

controlled. Confirm that a new USB detection icon (      ) appears in the 
windows taskbar. 

2.

Launch NetLinx Studio, select 

File

 > 

Open

, navigate to the assigned USB 

stick drive and open the 

cc-GuestPC Test.axs

 file. This file acts as a 

source for the various communication parameters needed by the Master 
to allow the initial communication between the panel and the PC.

3.

Scroll through the code in the 

cc-GuestPC TEST.axs

 file, and add the fol-

lowing information into your Master Source Code:

• Add a Telnet device connection to your device definitions by copying the 

following information from the 

DEFINE_DEVICE

 section (of the 

 

cc-GuestPC TEST.axs

 file) and pasting it into your source code: 

vdvGuestPC = 0:5:0

• Add the entire Module Definition: 

DEFINE_MODULE 'cc-GuestPCMod' <myModuleName> 

(<guestPcDevice>)

where:

<myModuleName>

  - local name for this instance of the cc-GuestPC 

module

<guestPcDevice> 

- device for cc-GuestPC to use for internal data 

events; this should be a DEFINE_DEVICE for the events to work properly

4.

Save and close the 

cc-GuestPC Test.axs

 file.

5.

Right-click the 

Module

 folder (in the Workspace containing your 

 

current Project), and select 

Add Existing Module File

.

6.

Navigate to the Module folder on the USB stick, and select 

*.tko

 from the 

Files of type

 field.

7.

Select the 

cc-GuestPC.tko

 file and click 

Open

 > 

OK

. This file needs to 

be added to your Workspace and compiled with the source code. 

8.

Save your Workspace, verify that your source code is designated as the 
Master source code file, and then press 

F7

 to begin compiling your 

 

Master Source Code and Module file. This process creates the .

tkn

 file 

that is transferred to the Master.

9.

Verify that your Master is online and communicating and select 

Tools

 > 

File Transfer

 to open the 

File Transfer

 dialog. Click the 

Add 

button

 

to 

open the Select Files for File Transfer dialog, open to the 

Current 

 

Workspace

 tab.

10. Locate the compiled 

*.tkn

 file and select it for transfer. Click 

OK

 to return 

to the File Transfer dialog.

11. Click 

Send

 to transfer the selected 

tkn

 file to the target Master.

Step 4:  Configure Computer Control

configCC.exe

 (included on the USB stick) is the Configuration Utility for 

G4CC. Use this application to designate up to four Modero or TPI/4 panels that 
will be allowed to control this computer.
1.

Use the computer’s file browser to navigate to the assigned USB stick 
drive location and open the 

Computer Control > Config

 folder.

2.

Use the 

configCC.exe

 application (on the USB stick) to configure the 

G4CC application. Double-click the 

configCC.exe

 to run the 

 

configuration utility.
The following information is needed by the Computer Control 

 

Configuration Utility (FIG. 3) for each G4 panel or TPI/4 interface:     

NetLinx Master IP Address/DNS 

(

Fixed IP/URL

):____.____.____.____

 

(Acquire the IP Address of the Master via NetLinx Studio: 

 

select Diagnostics > Network Addresses > Get IP Information).

G4 Touch Panel Device ID

: _______

 

(Acquire the panel device number in the online tree of NetLinx 

 

Studio).

G4 Touch Panel System

: _______

 

(Acquire the system number in the online tree of NetLinx Studio).

Computer Control Button Address Port

: _______

 

(Acquire this number via TPD4, in the Programming Tab of the Button 
Properties window).

Computer Control Button Address Code (Channel)

: _______

 

(Acquire this number via TPD4, in the Programming Tab of the Button 
Properties window). This information was previously entered into the 
Address Code field for the Computer Control button.

3.

Press the 

OK

 button when finished adding a single panel. This action 

 

modifies the 

amxCC.cfg

 file and stores your settings until the values 

within the 

configCC.exe

 file are altered. Once the USB Control Stick has 

been configured, it can be used on any computer residing on the Ethernet 
Network that can communicate with the NetLinx Control System. 

4.

Add multiple panels using the next (        ) button on the configuration 

 

utility screen (

maximum of four panels

).

Step 5:  Run the Computer Control Application

1.

Once the configuration file has been created, double-click the 

amxCC.exe

 file, located in the Computer Control folder, to begin your 

G4CC session and display the G4CC (      ) icon in the taskbar. The icon 
turns green (      ) when a Modero or TPI/4 panel is connected to the com-
puter. 

2.

Upon opening this file, your PC will be displayed on the touch panel.

3.

To terminate your Computer Control session, right-click on the G4CC icon 
and select 

Close Computer Control 

from the menu.

Step 6:  Run the TakeNote Application

If you are not using a direct RGB connection (such as on a TPI/4), G4CC must 
be running in order for TakeNote to function. Use the following steps to setup 
and implement TakeNote:
1.

Use the computer’s file browser to navigate to the USB stick drive and 
double-click the 

TakeNote

 executable to run the application.

2.

The TakeNote icon (       ) appears in the taskbar. 

• Double-click this icon to open the TakeNote Configuration page.
• Right-mouse click opens the TakeNote Context menu. Refer to the 

 

TakeNote Help file (F1) for more detailed information.

While you can have between 1 and 4 masters/panels connected to the PC you 
should not connect more than one PC to any one master/panel.