background image

For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).

1/09

©2009 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX.

AMX reserves the right to alter specifications without notice at any time. 

3000 RESEARCH DRIVE, RICHARDSON, TX 75082 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993 • www.amx.com

    93-2104

 

REV: B 

ICSNet Connections/Wiring

This connector uses a standard CAT5 Ethernet cable to provide 
communication between the CardFrame and the NetLinx control system 
processor. The following table shows the signal and pinout information 
associated with the ICSNet connections.    

Note: 

ICSHub cable information is used when connecting an NXF-MINI (from 

the rear ICSNet connector) to an external Hub (ex: ICSHub connector port on 
an NXC-NH).

ICSHub Connections/Wiring

The following table shows the ICSHub pinout wiring, coloring, and functionality.     

ICSNet Signals and Pinouts

Pin

Signal-Master

Signal-Device

1

TX  +

RX  +

2

TX  -

RX  -

3

N/A

N/A

4

GND

GND

5

N/A

N/A

6

N/A

N/A

7

RX +

TX +

8

RX -

TX -

ICSHub Pinout Information (EIA/TIA 568 B)

Pin

Wire Color

Polarity

Function

1

Orange/White

+

Transmit

2

Orange

-

Transmit

3

Green/White

-

-

4

Blue

-

-

5

White/Blue

+

-

6

Green

+

-

7

White/Brown

+

Receive

8

Brown

-

Receive

TIA 568B

1 2 3 4 5 6 7 8

1

 

2

 

3

 

4

 

5

 

6

 

7

 

8

 

RJ-45 connector - pin configurations

(female)

(male)

Reviews: