Wiring a Power Connection
To use the 2-pin 3.5 mm captive wire connector with a 12V
...
-compliant power
supply, the incoming PWR and GND wires from the external source must be
connected to their corresponding locations on the connector (FIG. 5).
The connector uses locking screws to insure a connection to the device, so
make sure to insert and tighten the screws before applying power.
PWR +
Power Supply
To the Touch Panel
GND -
FIG. 5
NETLINX POWER CONNECTOR WIRING DIAGRAM
1. Insert the PWR and GND wires on the terminal end of the 2-pin 3.5 mm
captive wire cable.
Match the wiring locations of the +/- on both the power supply and the
terminal connector.
2. Tighten the clamp to secure the two wires. Do not tighten the screws
excessively; doing so may strip the threads and damage the connector.
3. Verify the connection of the 2-pin 3.5 mm captive wire to the external
12V
...
-compliant power supply and apply power.
Powering On/Off Modero G5 Panels
Modero G5 touch panels may be powered on by touching and holding the
Sleep
button. To power off the panel, press and hold the Sleep button, and
select
Power Off
on the on-screen menu (FIG. 6):
FIG. 6
SLEEP BUTTON - PRESS AND HOLD TO ACCESS POWER OFF/SETTINGS OPTIONS
Configuration and Programming
Modero G5 touch panels are equipped with a
Settings
menu that provides the
ability to configure various features on the panels. To access the
Settings
menu,
press and hold the Sleep button, and select
Settings
.
Note: Information on the Settings menu, panel configuration, and programming
is provided in the Modero G5 Programming Guide, available at www.amx.com.
Setting the Panel’s Device Number and Device Name
1. In the Settings menu, select
NetLinx
. This opens a password keypad.
2. Enter the panel password into the keypad (the default is
1988
) and select
OK
to access the
NetLinx
page.
3. Press
Device Number
to open the NetLinx editing window.
4. Enter a unique Device Number assignment for the panel and press
OK
.
5. Enter a unique Device Name assignment for the panel and press
OK
.
Configuring the Panel’s IP Address
The first step is to configure the panel’s IP address. Note that this only configures
the panel to communicate with a network; it is still necessary to connect to the
NetLinx Master (
see Connecting to a NetLinx Master below
).
Network Communication via DHCP
1. In the
Ethernet
page, press
DHCP/Static
field to open the
DHCP/Static
window. Note that
DHCP
is the default setting.
2. Select
Host Name
, enter the new host name
3. Press
OK
to save changes.
Network Communication via Static Address
1. In the
Ethernet
page, press
DHCP/Static
to open the
DHCP/Static
window.
2. Select
Static
to open the
Static IP
window.
3. Press any field to open a keypad or keyboard (depending on the field), and
enter the appropriate network address information.
4. Press
OK
to save your changes and return to the
Ethernet
page.
Connecting to a NetLinx Master
To establish the type of connection to make between the panel and the
NetLinx Master:
1. In the NetLinx page, press
Mode
to choose the connection mode
(URL,
Listen or Auto)
:
CONNECTION MODES
Mode
Description
Procedures
URL
The device connects to the target
Master’s IP address via a TCP
connection.
1. Select
URL
in the Mode menu.
2. Enter the
Master IP/URL, Master Port Number
, and
Username/Password
(if required by the Master).
3. Press
OK
to save changes.
Listen
This mode allows the panel
to“listen” for the Master’s
communication signals.
Note that in this mode, the
System
Number
and
Master IP/URL
fields
are read-only.
1. Select
Listen
in the
Mode
menu.
2. Confirm the panel’s IP address is on the Master’s
URL list (via NetLinx Studio).
3. Press
OK
to save changes.
Note
: The Host Name (set on the Ethernet page), can
be used to locate the panel on the Master (
particularly
useful for DHCP connections where the IP address
can change
).
Auto
Use this mode when both the
panel and the NetLinx Master are
on the same Subnet.
1.
Sele
ct
Auto
in the
Mode
menu.
2. Enter the System Number and Username and
Password (if applicable).
3. Press
OK
to sav
e changes.
2. If password security is enabled on the target Master, enter the Username
and Password:
a. Select
Username
to open the
NetLinx
window.
b. Enter the
Username
and
Password
required by the Master.
c. Press
OK
to save changes and return to the
NetLinx
page.
Related Software and Additional Documentation
(at www.amx.com)
• Programming the Modero G5 touch panel requires the use of either Rapid
Project Maker (RPM) or the latest version of Netlinx Studio and TPDesign5,
both available to download at www.amx.com. Refer to the NetLinx Studio
and TPDesign5 online help for information.
• For information on designing touch panel pages intended to optimize the
Modero G5 experience, refer to the G5 Considerations Guide.
• For additional information on the MT-2002 panel, refer to the
Modero G5
Touch Panel Instruction Manual
.
• For detailed information on the Settings menu as well programming
information and instructions on upgrading firmware, refer to the
Modero G5
Programming Guide
.
• Detailed specifications drawings for the MT-2002 are available to download
from www.amx.com.
© 2018 Harman. All rights reserved. Modero X and Modero X Series, AMX, AV FOR AN IT WORLD, and HARMAN, and their respective logos are
registered trademarks of HARMAN. Oracle, Java and any other company or brand name referenced may be trademarks/registered trademarks
of their respective companies. AMX does not assume responsibility for errors or omissions. AMX also reserves the right to alter specifications
without prior notice at any time. The AMX Warranty and Return Policy and related documents can be viewed/downloaded at www.amx.com.
3000 RESEARCH DRIVE, RICHARDSON, TX 75082 AMX.com | 800.222.0193 | 469.624.8000 | +1.469.624.7400 | fax 469.624.7153
AMX (UK) LTD, AMX by HARMAN - Auster Road, Clifton Moor, York, YO30 4GD United Kingdom • +44 1904-343-100 • www.amx.com/eu/
LAST REVISED: 09/12/2018