Accessing the Setup Pages

The MVP-5150 features on-board 

Setup

 pages. Use the options in the 

Setup

 

pages to access panel information and make various configuration changes. 
To access the 

Setup

 pages, use the included stylus tip to press the recessed 

button on the left top side of the device and hold for three seconds. A popup 
screen opens that reads “Release button now to enter the Setup Pages. 
Continue holding to enter Calibration.” Releasing the recessed button at that 
time opens the main 

Setup

 page.

For more information, refer to the 

Setup Pages

 section of the 

MVP-5100/50 

Modero ViewPoint Touch Panel Operation/Reference Guide

, available at 

www.amx.com

.

Accessing the Calibration Page

The 

Calibration

 page allows you to calibrate the touch panel for accurate button 

selection.
1.

Press and hold the recessed button on the left side of the device until a 
screen appears that reads “Release button now to enter Calibration 
Page, Continue holding to shut down panel”. Release the button to open 
the 

Calibration

 page.

2.

Press the crosshairs to calibrate the panel and return to the previous 
page. 

3.

This page may also be accessed through the

 Protected Setup

 page.

4.

Always calibrate the panel before its initial use, and after downloading 
new firmware.

Accessing the Protected Setup Page

The 

Protected Setup

 page provides secured access to advanced panel 

configuration options, including communication and security settings. Enter the 
factory default password (

1988

) into the password keypad to access this page. 

Setting the Panel’s Device Number

In the 

Protected Setup

 page:

1.

Press the 

Device Number

 field to open the 

Device Number

 keypad.

2.

Enter a unique Device Number assignment for the panel, and press 

Done

 

to return to the 

Protected Setup

 page. The Device Number range is 1 - 

32000, and the default is 0.

Configuring the Panel’s Wireless IP Settings

The first step to successfully setting up the internal wireless card is to configure 
the IP Settings section on the 

Wireless Settings

 page. This section configures 

the communication parameters from the MVP panel to the web.

Wireless Communication Using a DHCP Address

In the 

Protected Setup

 page:

1.

Select 

Wireless Settings

. Wireless communication is set within the 

 

IP Settings

 section of this page.

2.

Toggle the 

DHCP/Static

 field (from the 

IP Settings

 section) until the 

choice cycles to DHCP. This action causes all fields in the

 IP Settings

 

section other than Host Name to be greyed-out. Once the panel is 
rebooted, these values are obtained by the unit and displayed in the DNS 
fields after power-up.

NOTE:

 DHCP will register the unique MAC Address (factory assigned) on 

the panel and once the communication setup process is complete, assign 
IP Address, Subnet Mask, and Gateway values from the DHCP Server.

3.

Press the optional 

Host Name

 field to open a Keyboard and enter the 

Host Name information.

4.

Press 

Done

 after you are finished assigning the alpha-numeric string of 

the host name.

Configuring the Card’s Wireless Settings

The second step of a successful setup of the wireless card is to configure the 
Wireless Security section of the 

Wireless Settings

 page. This section 

configures both the communication and security parameters from the internal 
wireless card to the WAP.

Configuring the Wireless Card for Secured Access to the WAP

In the 

Protected Setup

 page:

1.

Select 

Wireless Settings

.

2.

Press the 

Site Survey

 button to access the 

Wireless Site Survey

 page.

3.

Select a WEP secured WAP from within the Wireless Site

 Survey

 page, 

as displayed in the 

Security

 field, and press the 

Connect

 button to dis-

play the 

Static WEP Settings

 popup.

4.

Enter the key length and values for matching the WAP and press 

Save

.

5.

The 

Access Point MAC Address

 field will now be filled.

6.

Press 

Back

 to return to the 

Protected Setup

 page.

Consult the 

MVP-5100/50 Modero ViewPoint Touch Panel Operation/

Reference Guide

 for steps for manual entry of the SSID information.

Choose a Master Connection Mode

The panel requires the establishment of the type of connection to be made 
between it and the master.
In the

 Protected Setup

 page:

1.

Select 

System Settings

.

2.

Select 

Type

 to toggle between the Master Connection Types 

USB

 and 

Ethernet

.

A USB connection is a direct connection from the panel’s mini-USB port 
to a corresponding USB port on the PC (acting as a Virtual Master).
A Wireless Ethernet connection involves indirect communication from the 
panel to a Master via a wireless connection to the network.

Upgrading Firmware Via the USB Port

The MVP-5150 uses a 5-pin CC-USB (Type A) to Mini-B 5-Wire programming 
cable (

FG10-5965

) for programming, firmware updates, and touch panel file 

transfer between the PC and the target device. If a programming cable is not 
available, it may be purchased from

 www.amx.com

Before beginning the upgrade, verify that the device is powered and the Type-A 
end of the USB connector is inserted and secure the PC’s USB port. The panel 
must be powered 

On

 before connecting the mini-USB connector to the panel. 

To guarantee that the upgrade is not interrupted by power loss, connecting the 
device to a power source, such as putting it in a Table Charging Station, before 
beginning the upgrade is highly recommended.

Step 1: Configure the panel for a USB Connection Type

1.

After completing the installation of the USB driver, confirm the proper 
installation of the large Type-A USB connector to the PC's USB port, and 
restart the PC.

2.

After the panel powers up, hold the reset button to display the 

Setup Page

 

and open the 

Protected Setup

 page.   

3.

Press 

System Settings

 to open the 

System Settings

 page. 

4.

Toggle the blue 

Type

 field in the 

Master Connection

 section until the 

choice cycles to 

USB

NOTE:

 

ALL

 fields are then grayed out and 

 

read-only. However, they still display any previous network information.

5.

Press the 

Back

 button on the touch panel to return to the 

Protected Setup

 

page.

6.

Press the 

Reboot

 button to both save any changes and restart the panel. 

Remember that the panel’s connection type must be set to 

USB

 prior to 

rebooting the panel and prior to inserting the USB connector.

7.

ONLY AFTER the unit displays the first panel page should you THEN 
insert the mini-USB connector into the Mini-USB Port on the panel. It may 
take a minute for the panel to detect the new connection and send a 

 

signal to the PC, indicated by a green 

System Connection

 icon. 

8.

Navigate back to the 

System Settings

 page.

For more information, refer to the 

Upgrading Firmware

 section of the 

MVP-

5100/50 Modero Viewpoint Touch Panel Operation/Reference Guide

, available 

at 

www.amx.com

.

Cleaning the Touch Overlay and Case

The touch screen overlay should be cleaned after each day’s use to maintain 
the appearance of the device. Always use a clean cotton cloth and a spray 
bottle containing water or a vinegar-based cleaner, as alcohol-based cleaners 
can damage the device. 

Do not directly spray the device

: instead, spray the 

cloth to clean the touch screen overlay. Do 

NOT

 use an abrasive of any type to 

clean the MVP-5150, as this may permanently damage or remove the device’s 
finish.

Battery Life and Replacement

The battery powering the MVP-5150 is designed for upwards of 300 deep 
discharge rechargings. Regular shallow rechargings will extensively increase 
expected battery life, and the device should be stored in either a Table 
Charging Station or Wall Charging Station when not in use to keep it at an 
optimum charge. The battery has reached its effective end of life after it can no 
longer hold more than a 70 percent charge.
The battery included with the MVP-5150 may be replaced with the MVP-BP-
51H High Capacity Battery Pack Kit (

FG5966-24K

) for longer battery life. This 

kit contains the parts necessary to install the new battery, and may be 
purchased from 

www.amx.com.