Wiring and Device Connections
44
Enova DVX-315xHD & DVX-215xHD All-in-One Presentation Switchers - Instruction Manual
FIG. 56 provides wiring requirements for the AxLink connector:
FIG. 56
Mini-Phoenix Connector Wiring Diagram (Direct Data And Power)
To use the 4-pin 3.5 mm mini-Phoenix (female) captive-wire connector for data communication and power transfer, the incoming
PWR and GND cable from the 12 VDC-compliant power supply must be connected to the AxLink cable connector going to the All-In-
One Presentation Switcher. FIG. 57 shows the wiring diagram.
FIG. 57
4-pin Mini-Phoenix Connector Wiring Diagram (Using External Power Source)
WARNING: When you connect an external power supply, do not connect the wire from the PWR terminal (coming from the
external device) to the PWR terminal on the Phoenix connector attached to the Controller unit. Make sure to connect only the
AXM, AXP, and GND wires to the Controller’s Phoenix connector when using an external power supply.
Make sure to connect only the GND wire on the AxLink/PWR connector when using a separate 12 VDC power supply. Do not
connect the PWR wire to the AxLink connector’s PWR (+) opening.
Power Connector/Switch/Fuse
FIG. 58 displays the power switch and connector for the DVX.
FIG. 58
Power Connector/Switch/Fuse
WARNING: This unit should only have one source of incoming power.
Using more than one source of power to the Controller can result in damage to the internal components and a possible burn out.
CAUTION:
Apply power to the unit only after you have completed installing the device.
CAUTION:
To reduce the risk of electric shock, grounding of the center pin of the power plug must be maintained.
Top view
Top view
To the Controller’s
AxLink/PWR connector
To the external AxLink device
Top view
Top view
To the Controller’s
AxLink/PWR connector
To the external AxLink device
Local 12+ VDC
power supply
(coming from an
external
power supply)
Power switch
Fuse (2.5A)
Power cable connector