Enova DVX-315xHD & DVX-215xHD All-in-One Presentation Switchers - Instruction Manual
Installation
Overview
This chapter provides information on installing a DVX into an equipment rack.
Mounting the DVX into an Equipment Rack
The DVX occupies three rack units in a standard equipment rack. The following steps apply to mounting the DVX.
1.
Discharge any static electricity from your body by touching a grounded metal object.
2.
Position and install the mounting brackets, as shown in FIG. 4, using the supplied mounting screws.
NOTE:
The left and right mounting brackets are not identical. Please install in the orientation shown.
FIG. 4 displays how the brackets should be attached to the DVX:
FIG. 4
Rack Mounting the DVX
3.
Install the DVX in the mounting rack by using the mounting screws to affix the unit to the rack.
4.
Connect any applicable wires to the DVX. Refer to the
section on page 22 for wiring diagrams
and pinout descriptions.
WARNING: DO NOT stand other units directly on top of the DVX when it is rack mounted, as this will place excessive strain on the
mounting brackets.
Ventilation
ALWAYS ensure that the rack enclosure is adequately ventilated. Do not block any ventilation openings. Sufficient airflow must be
achieved (by convection or forced-air cooling) to satisfy the ventilation requirements of all the items of equipment installed within
the rack.
WARNING: The maximum operating ambient temperature is 40°C (104°F).
WARNING: When installing equipment into a rack, distribute the units evenly. Otherwise, hazardous conditions may be created
by an uneven weight distribution.
Reliable earthing (grounding) of rack-mounted equipment should be maintained.
The DVX should not be installed in enclosed spaces. It is recommended to leave 1 RU of space above the DVX when installing in a
rack.
Brackets attach at the side
toward the front of the unit