24
USER MANUAL - DUX-SRX
100-METER 4K HDBASET SCALING RECEIVER
IDX
Function Description
More Details
Syntax
Example
29
To Set Input EDID
Command:
CE#T
Return:
CE#T
Description:
E# : # = {1 ~ 13}
1 : 3840x2160@30_2ch
2 : 1920x1200@60_2ch
3 : 1920x1080@60_2ch
4 : 1280x800@60_2ch
5 : 1280x720@60_2ch
6 : 1024x768@60_2ch
7 : 3840x2160@30_6ch
8 : 1920x1200@60_6ch
9 : 1920x1080@60_6ch
10: 1280x800@60_6ch
11: 1280x720@60_6ch
12: 1024x768@60_6ch
13: copy
Command:
CE1T
Return:
CE1T
Description:
Set input FIX EDID max timing
3840x2160@30_2ch
30
Uart Connection
Command:
CCON#T
Return:
CCON#T
Description:
CON# : # = {1 ~ 4}
1 : uart to vs
2 : uart to vs_update
3 : uart to scaler
4 : vs to scaler
Command:
CCON1T
Return:
CCON1T
Description:
Connect uart to vs.
31
To verify uart connection status
Command:
SCONT
Return:
SCONT( # )
Description:
# : # = {1 ~ 4}
1 : uart to vs
2 : uart to vs_update
3 : uart to scaler
4 : vs to scaler
Command:
SCONT
Return:
SCONT( 1 )
Description:
Uart connection status is to vs.