Flat Surface Installation

It is recommended that you cutout the surface slightly smaller than what is outlined in 
the installation drawings so that you can make any necessary cutout adjustments.

Before you begin, if you are using the 2-pin power connector, verify that the terminal 
end of the power cable is not connected to a power source

1.

If assembled, remove the Mio Modero DMS from the backbox. Place a flathead 
screwdriver between the tab of the backbox and the notch of the Mio Modero 
DMS (see FIG. 2) and pry the two apart.

2.

Cut out the surface for the Mio Modero DMS backbox using the dimensions 
shown in FIG. 3. A template is included to help you determine dimensions.    

3.

Thread the CAT5/CAT6 and, if necessary, the power cables through one of the 
provided breakaway access points on the backbox. Leave enough slack in the 
wiring to accommodate any re-positioning of the unit.

4.

Insert the backbox into the cutout until the rim of the backbox is flush against 
the wall.

5.

Insert and secure four #4-40 mounting screws (not included) into their 
corresponding holes located along the sides of the backbox until it is flush 
against the wall. Or use expansion clips at this time.

6.

Connect the 2-pin power connector and/or CAT5/CAT6 cables in the back of 
the Mio Modero DMS. See FIG. 2 for port locations.

7.

Insert and fasten the Mio Modero DMS into the backbox, start at the top of the 
device and tilt in toward the bottom.

Device Setup

The Mio Modero DMS Pinnacle is equipped with firmware pages that allow you to set 
and configure various features of the device. Some menu items are compulsory, 

Necessary Device Setup

, while other items are optional, 

Optional Device 

Setup

section on page 28

 of the instruction manual.

To navigate the pages in the Mio Modero DMS Pinnacle, press 

More...

 to view more 

options within the selected menu. Press 

Return

 to go back a page and accept 

changes made.  

Note:  

Confirm your NetLinx master has the latest version of Nexus compliant 

firmware. The firmware must be UDP and NDP settings compliant (v.323 or higher).

Accessing The Setup Page

If you have not loaded any pages on your Mio Modero DMS device, it will launch the 
Setup page by default. Otherwise, press and hold in the middle of the slider for 3 
seconds.

Necessary Device Setup

The following sections must be set on your Mio Modero DMS Pinnacle.

Device Calibration

From the Setup page, follow these steps:

1.

Select 

Protected Setup. 

If you do not have a password established on the Mio 

Modero DMS Pinnacle, the device will not prompt you for one. Default pass-
word is 

1988

2.

Select 

Calibrate

.

3.

Touch each target on the screen as they appear. Once calibrated the Mio Mod-
ero DMS Pinnacle confirms and instructs you to touch the screen to continue.

You can now select 

Return

 and go back to the Setup page.

IP Settings

The configuration of the Mio Modero DMS Pinnacle requires you set the 
communication protocol. Your options are either Static or DHCP. Consult the 

Mio 

Modero DMS & Mio Modero DMS Pinnacle

 instruction manual for setting Static. 

From the Setup page, follow these steps:

1.

Push 

Protected Setup

. If you do not have a password established, the device 

will not prompt you for one.

2.

Select 

IP Settings

.

3.

Select 

DHCP

.

4.

In the DHCP page, select 

DHCP

 to toggle the protocol between 

DHCP

 and 

Static

.

5.

Select 

Return

 to accept that change.

Consult the 

Mio Modero DMS & Mio Modero DMS Pinnacle

 instruction manual for 

setting a Host Name.

DMS Pinnacle Menu Navigation

Follow these tips to set your device information:

• Touch the top of the slider to move 

UP

 and the bottom of the slider to move 

DOWN

 

through numerals.

Accept Char

 enters the current value and moves the cursor to the right.

Backspace

 moves the cursor to the left.

Clear

 removes everything listed.

Abort

 exits the edit page without keeping changes.

Done

 accepts changes and returns to the previous page.

Master Connection

The Mio Modero DMS Pinnacle requires you establish the type of connection you 
want made between it and your master. From the Setup page, follow these steps:  

1.

Select 

Protected Setup

. If you do not have a password established, the device 

will not prompt you for one.

2.

Select 

Master Connection

.

3.

Select 

Connection Mode

.

4.

Select the listed mode to toggle through the available connection modes:    

5.

Select 

More...

 to view the second page of the 

Master Connection

 menu.

6.

Select 

Master Port

. The default setting for the port is 

1319

. Select the master 

port number to access the edit page and change this value.
See 

DMS Pinnacle Menu Navigation

 for help.

7.

After you have set your Master Port and selected 

Done

, select 

Return

 to 

finalize your changes and go back to the 

Master Connection

 page.

If you have enabled password security on your master you need to set the username 
and password within the device.

8.

Select 

Username

. If no username has been set, the field is blank. Select the 

blank field just below

 Username

.

See 

DMS Pinnacle Menu Navigation

 for help.

9.

After you have set your Username and selected 

Done

, select 

Return

 to finalize 

your changes and go back to the 

Master Connection

 page.

10.

Select 

More...

11.

Select 

Password

. If no password has been set, the field is blank. Select the 

blank field just below

 Password

.

See 

DMS Pinnacle Menu Navigation

 for help.

12.

After you have set your Password and selected 

Done

, select 

Return

 to finalize 

your changes and go back to the 

Master Connection

 page.

13.

Reboot device to confirm changes.

FIG. 3  

Mio Modero DMS Installation Using Either Expansion Clips or #4-40 Screws

(2 PROVIDED)

DRYWALL EXPANSIONS CLIPS

IF UNIT IS INSTALLED USING

THIS NOTCH IS ONLY NEEDED

THESE 4 HOLES ARE ONLY REQUIRED
WHEN MOUNTING UNIT TO A SOLID

SECURE UNIT WITH #4 SCREWS. 

SURFACE (PODIUM, DESK, ETC.).

BEZEL OUTLINE

CUTOUT

Only required for
solid surface mounting.
Use #4 screws.

Notch

Connection Modes

Mode

Description

Procedures

Auto

The device connects to the 
first master that responds. 
This setting requires you set 
the System Number, this set-
ting is available in the 

Master 

Connection

 menu.

Setting the System Number:

1.

Within the 

Master Connection

 menu, 

select 

System Number

.

2.

To change the System Number from what 
is listed, select the System Number to 
enter the edit page.

See 

DMS Pinnacle Menu Navigation

 for help.

3.

After you have set your System Number 
and selected 

Done

, select 

Return

 to 

finalize your changes and go back to the 

Master Connection

 page.

URL

The device connects to the 
specific IP of a master via a 
TCP connection. This setting 
requires you set the Master’s 
IP.

Setting the Master IP:

1.

Select 

More...

2.

Select 

Master IP

.

3.

To change the Master IP from what is 
listed, press the button next to the Master 
IP number to enter the edit page.

See 

DMS Pinnacle Menu Navigation

 for help.

4.

After you have set your Master IP and 
selected 

Done

, select 

Return

 to finalize 

your changes and go back to the 

Master 

Connection

 page.

Listen

The device "listens" for the 
master to initiate contact. 
This setting requires you 
provide the master with the 
device’s IP.

Confirm device IP is on the Master URL list. You can set 
the Host Name on the device and use it to locate the 
device on the master. Host Name is particularly useful in 
the DHCP scenario where the IP address can change.

NDP 
(UDP)

The device is available via 
Nexus Discovery Protocol.

Use the master web interface, NetLinx Studio or 
commands to bind the DMS device to the master.

URL 
(UDP)

The device connects to the 
specific IP of a master via 
UDP.

Setting the Master IP:

1.

Select 

More...

2.

Select 

Master IP

.

3.

To change the Master IP from what is 
listed, press the button next to the Master 
IP number to enter the edit page.

See 

DMS Pinnacle Menu Navigation

 for help.

4.

After you have set your Master IP and 
selected 

Done

, select 

Return

 to finalize 

your changes and go back to the 

Master 

Connection

 page.

Reviews: