Wiring guidelines

The following table lists copper wire sizes and maximum lengths allowable 
between the AXB-FBM and the Master Controller's power supply. When 
these distances are exceeded, a separate, optional 12 VDC power supply 
is used to power the AXB-FBM. The maximum wiring lengths are based 
on 12 VDC available at the Master Controller's power supply output.

Wiring AXlink and Auxiliary 12 VDC Power

Figure 3 diagrams wiring the AXlink and a 12 VDC auxiliary power supply 
to the AXB-FBM. 

Use the 12 VDC power supply when the distance between the Master 
Controller and AXB-FBM exceeds the limits described in Figure 3. Make 
sure to connect only the GND wire on the AXlink connector when using a 
12 VDC power supply. Do not connect the PWR wire to the AXlink 
connector's PWR opening.

Wiring Guidelines

Wire Size

Max Wiring Length

18 AWG

918.62 ft.

280.0 m

20 AWG

581.19 ft.

177.1 m

22 AWG

362.35 ft.

95.2 m

24 AWG

228.40 ft.

69.6 m

FIG. 3  

Auxiliary 12 VDC power supply wiring diagram

PWR+

AXP/TX

AXM/RX

GND-

PWR+
AXP

AXM

GND-

AXlink connector on

AXB-FBM

External equipment

PWR+

GND-

Local 12 VDC power supply

PWR connector on

AXB-FBM