Quick Start Guide

AXD-IR+

 WallMount Remote IR Receiver

Overview

The AXD-IR+ (FIG. 1) is a remote IR receiver for use with both AMX 
Axcess/NetLinx Central Controllers and operates via the AXlink bus to 
remotely control AXlink devices. The AXD-IR+ is in a UniMount wall panel 
that fits into most US-style single-gang enclosures. The AXD-IR+ works 
with AMX 38 kHz or 455 kHz IR transmitters.

Note:

 The AXR-IRSM+ swivel-mount version is also available for wall or 

ceiling installations:

Wiring and Installation

Set the receive frequency, AXlink device number and IR validation level 
before installing the AXD-IR+. FIG. 2 illustrates the location of key 
components on the AXD-IR+ circuit board.

Setting the Receive Frequency

Use the set of jumper pins on the corner of the circuit board to set the 
receive frequency. FIG. 3 illustrates the configuration of the jumpers..

Note: The unit will not operate with one set of pins configured for 
38 kHz and the other set of pins configured for 455 kHz.

To receive 455 kHz (

default setting

), position both jumpers on pins 

1 and 2 (away from the edge of the circuit boards).

To receive 38 kHz, position both jumpers on pins 2 and 3 (near the 

edge of the circuit boards).

Setting the AXlink Device Number

1.

Locate the 8-position Device DIP switch (FIG. 2). 

2.

Set the DIP switch according to the DIP switch values shown below.

The device number is set by the total value of DIP switch positions that 
are ON (down). The Axcess software program in your system typically 
uses device numbers 128 through 255 for the panels.

As an example, the DIP switch in FIG. 4 defines device number 129 
(1+128=129).   

Note: If you later change the device number, remove and reconnect 
the AXlink connector to enter the new device number into memory.

Sensor IR Validation Level

The IR validation level is set on the receiving device (such as an 
AXC-RCVI). 

Setting the IR Validation Level

An IR transmitter must send repetitions of data for the receiver to accept it 
as valid data. In some installations, a light wall color or other physical 
condition may interfere with the sensor's or receiver's ability to sense the 
transmitted signal. The signal may reflect or bounce and become distorted. 
The receivers can be set to use either two or three repetitions of sequential 
signals to validate and accept the signal data. 

Perform the following steps to set the receiver's IR level.

1.

Locate the IR jumper pins (J1) (FIG. 5) on the circuit board (FIG. 2).

2.

Position the IR validation jumper (FIG. 5) to select the number of valid 
IR data repetitions to be accepted:

Position the jumper at 2 to have the unit validate 2 sequential signals.

Position the jumper at 3 to have the unit validate 3 sequential signals.

Wiring the IR Sensors and Receivers

The AXD-IR+ uses a 4-pin AXlink connector for power and data. If the 
distance between the receiver and Central Controller exceeds power 
consumption limits, you can connect a local 12 VDC power supply to the 
AXlink connector.

FIG. 1  

AXD-IR+ UniMount IR receiver

AXD-IR+ Specifications

Dimensions (HWD):

4.68" x 2.93" x 1.44" (118.87 mm x 74.42 mm x 36.58 mm) 

Available Colors:

White (

FG456-10

) and Black (

FG456-11

)

Receive Frequencies:

38 / 455 kHz (user-selectable)

Mounting:

Mounts into most US-style single-gang enclosures.

Weight:

7.8 oz. (218.4 g)

Power Consumption:

35 mA

FIG. 2  

Location of key components on the AXD-IR+ circuit board

FIG. 3  

Receive frequency jumper settings

 

AXlink Device

IR Validation

AXlink 

DIP Switch

Jumper Pins

Connector

Receive Frequency
Jumper Pins

8-position

IR SNSR
38/455
kHz

Setting for 455 kHz

IR SNSR
38/455
kHz

Setting for 38 kHz

Switch

1 2 3 4

5

6

7

8

Value

1 2 4 8 16 32 64 128

FIG. 4  

Example Device DIP Switch set to 129

FIG. 5  

IR validation jumper pin settings

Setting for 2 validations

Setting for 3 validations

2

3

2

3

J1

J1