Overview

Devices that require a simple momentary or latching contact closure can be 
controlled with the AXC-REL8 Universal Eight Relay Card (FIG. 1). This 
card can operate up to 8 relay-controlled functions; cards can be linked 
together, allowing a larger number of functions. Adjacent relays on the card 
may be selectively commoned to reduce device wiring.  

Specifications

The table below provides specification information for the AXC-REL8 
(

FG715

).    

Connections

The table below lists the AXC-REL8 pinout connectors. 

Commons

The table below lists the commons for the AXC-REL8 if installed in the On 
position.  

Relay Status LED Indicators

The table below provides a description for the illumination of each relay 
LED. Refer to FIG. 2 for a visual reference of LED locations.         

FIG. 1  

AXC-REL8 Universal Eight Relay Card (side view)

Specifications

Power 
Consumption:

• 150 mA, 12 VDC

Contact 
Closures:

• 8  per  card

Relays:

• Single pole double throw (SPDT). 
• Each relay is individually assignable as normally open 

(NO) or normally closed (NC) via jumpers provided on the 
card.

Jumpers:

• JP1: Installed between center pin and NC, relay 1 is 

Normally Closed; installed between center pin and NO, 
relay 1 is Normally Open.

• JP2: Same as JP1 for relays 2 - 8, respectively a jumper 

must be in one of these locations for each relay used.

LEDs:

• CR1 - 8: Indicates energized condition of corresponding 

relay

Contact Rating:

• 1 A @ 24 VAC / 28 VDC 
• 750 mA MAX resistive load.

Pinout Connectors

Pinout

Description

1

Common #1

2

Contact #1

3

Common #2

4

Contact #2

5

Common #3

6

Contact #3

7

Common #4

8

Contact #4

9

Common #5

10

Contact #5

11

Common #6

12

Contact #6

13

Common #7

14

Contact #7

15

Common #8

16

Contact #8

Commons

Commons

Description

CO1 - 2

Connects Common #1 to Common #2.

CO2 - 3

Connects Common #2 to Common #3.

CO3 - 4

Connects Common #3 to Common #4.

CO4 - 5

Connects Common #4 to Common #5.

CO5 - 6

Connects Common #5 to Common #6.

CO6 - 7

Connects Common #6 to Common #7.

CO7 - 8

Connects Common #7 to Common #8.

Relay Status LEDs

Relay LED #

Description

CR1 (top LED)

Indicates the energized condition of relay 1.

CR2

Indicates the energized condition of relay 2.

CR3

Indicates the energized condition of relay 3.

CR4

Indicates the energized condition of relay 4.

CR5

Indicates the energized condition of relay 5.

CR6

Indicates the energized condition of relay 6.

CR7

Indicates the energized condition of relay 7.

CR8

Indicates the energized condition of relay 8.