background image

For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).

4/07

©2007 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX.

AMX reserves the right to alter specifications without notice at any time. 

3000 RESEARCH DRIVE, RICHARDSON, TX 75082 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993 • www.amx.com

 93-5927-01

 

REV: A 

The table below lists wire sizes and maximum lengths allowable between the 
AXB-DMX512 and Central Controller. The maximum wiring lengths for using 
AXlink power are based on a minimum of 13.5 volts available at the Central 
Controller’s power supply.       

Using AXlink communication

Connect the AXlink wiring to the connector on the AXB-DMX512, as shown in 
FIG. 5.

DMX512 data communication

Note

: Some DMX devices only use DATA+ and DATA-. Connect these to 

DATA1+ and DATA1-, leaving DATA2+ and DATA- unconnected. The DATA2 In 
and Out ports are not currently supported.

Transmit Wiring

For transmit wiring, connect the DMX512 wiring to the OUT connector, as 
shown in FIG. 6.

Receive Wiring

For receive wiring, connect the DMX512 wiring to the IN connector, as shown 
in FIG. 7.

Mounting the AXB-DMX512 in a Rack

To mount the AXB-DMX512 in an equipment rack, you will need an AC-RK rack 
mounting kit.
1.

Remove the two screws on the front panel of the AXB-DMX512.

2.

Remove the front panel and the space bracket behind the panel. 

3.

Remove the rubber feet on the bottom of the unit, if necessary. Insert a 
scissors blade or other sharp object into the side of one of the rubber feet 
and pull it off. Do the same to remove the other three rubber feet.

4.

Place the unit in the appropriate opening in the AC-RK. 

5.

Place the front panel of the AXB-DMX512 on the front of the rack over the 
unit and secure the screws.

Replacing the Lithium Battery

A lithium battery (FIG. 8) with a life of approximately 5 years, protects stored 
presets if a power loss occurs. The battery is not used when DC power is 
supplied to the AXB-DMX512. Write down the replacement date on a sticker or 
label by adding 5 years to the date of installation, and then attach it to the 
bottom of the AXB-DMX512.   

Note

: All control commands in AXB-DMX512 memory are lost when the lithium 

battery is replaced

Contact your AMX dealer before you replace the lithium battery and verify that 
they have a current copy of the Axcess program for your AXB-DMX512. This 
will avoid any inadvertent loss of data or a service outage.
You will need a flat-blade tool (non-conducting) that can be slipped under the 
lithium battery to pry it up and out of the socket.

Note

: Static electricity can damage electronic circuitry. Before removing the 

lithium battery from the enclosure, discharge any accumulated static electricity 
from your body by touching a grounded metal object.

1.

Discharge the static electricity from your body.

2.

Unplug all cables from the AXB-DMX512.

3.

Remove the AC-RK and AXB-DMX512 from the mounting rack. Other-
wise, go to step 4.

4.

Remove the five pan-head screws on the top of the AXB-DMX512 enclo-
sure. 

5.

Pull the two enclosure halves apart and set the bottom portion of the 
enclosure on a flat surface.

6.

Locate the battery on the circuit card.

7.

Carefully pry the battery out of its socket and insert the new battery. Write 
down the next replacement date on a sticker or label by adding 5 years to 
the replacement date, and then attach it to the bottom of the AXB-
DMX512.

8.

Plug all cables back into the AXB-DMX512.

9.

Place the top portion of the enclosure back onto the bottom portion. Then, 
refasten the five pan-head screws.

10. Reconnect the cables removed for battery replacement.

Note

: There is a danger of explosion if you replace the battery incorrectly. 

Replace the battery with the same or equivalent type recommended by the 
manufacturer. Dispose of used battery according to the manufacturer's 
instructions. Never recharge, disassemble, or heat the battery above 212 °F 
(100 °C). Never solder directly to the battery or expose the contents of the 
battery to water.

Wiring Guidelines at 160 mA

Wire Size

Maximum Wiring Length

18 AWG

733.57 feet (223.59 m)

20 AWG

464.11 feet (141.46 m)

22 AWG

289.35 feet (88.19 m)

24 AWG

182.39 feet (55.59 m)

FIG. 5  

AXlink wiring

FIG. 6  

DMX512 transmit wiring

FIG. 7  

DMX512 receive wiring

PWR
AXP
AXM
GND

PWR

AXP

AXM

GND

Device

AXlink connector

on AXB-DMX512

DMX 512 OUT

connector on AXB-DMX512

GND

DATA1-

DATA1+

DATA2-

DATA2+

NC

GND

DATA1-

DATA1+

DATA2-

DATA2+

Device

DMX 512 IN

connector on AXB-DMX512

GND

DATA1-

DATA1+

DATA2-

DATA2+

NC

GND

DATA1-

DATA1+

DATA2-

DATA2+

Device

FIG. 8  

Lithium battery and socket

Battery (CR2032 type - 20mm coin cell)

socket

Reviews: