IMPORTANT: SAFETY INSTRUCTIONS

This manual provides you with important information about the Humidifier and should be 

read carefully to ensure the safe and proper use of this product. 

Read and understand all the safety and operating instructions contained in this booklet 

before using this product.

If you do not understand these instructions, or have any questions, contact your supervisor, 

dealer or the manufacturer before attempting to use the apparatus.

   

  

Indicates a potentially hazardous situation, which if not avoided, could result in    

 

death or serious injury.

ATTENTION:

  Indicates a potentially hazardous situation, which if not avoided, could result in    

 

minor or moderate injury.

CAUTION:

 

              Indicates  a  potentially  hazardous  situation,  which  if  not  avoided,  could  result  in                                

 

property damage.

 

 

Consult operating manual 

 

Use no oil

Receiving  Inspection   

 

 

 

 

 

 

         

Remove product from package and inspect for damage. If product is damaged or incorrect, do 

not use. Contact your dealer, equipment provider or manufacturer.

ATTENTION: 

It is very important to allow product to remain in original packaging for  

                              24 hours to acclimate to room temperature before use. 

ATTENTION:

  Store the product in a sealed package to avoid environmental damage. The     

 

 

operating and storage temperature for the Humidifier should reflect typical    

 

              environmental conditions of a medical facility environment.

User 

Responsibility 

       

 

      

 

Service of this device should ONLY be performed by properly trained  

 

 individuals.

This product performs as explained in this manual as long as the assembly, use, repair and 

maintenance are properly followed according to our instructions. Periodic review of this device  

is recommended.  If any damage or defects are present, the product should not be used. This  

includes parts that are worn or missing.  If any of the above are noted, immediate repair/ 

replacement is required. If this device is subject to improper maintenance, repair, use and/or 

abuse leading to malfunction of the device, replacement is the sole responsibility of the user.

      

 

Due to the possibility of explosion caused by static charge, DO NOT operate  

 

        this device near flammable anesthetics.

 

 

Always ensure that the Pressure Relief Valve is in place and operational  

 

        prior to using the Humidifier.

ATTENTION:

  Keep the Humidifier in a clean area when not being used.

!  

WARNING: 

!  

!  

WARNING: 

!  

WARNING: 

!  

WARNING: 

Summary of Contents for FM-HUMID-R

Page 1: ... 1111 Lakeside Drive Gurnee IL 60031 4099 Tel 1 800 448 0770 Fax 847 855 6300 www ohiomedical com 25B East Pearce St Richmond Hill ON L4B 2M9 Canada Tel 905 764 7736 Fax 905 764 7743 www amvex com Rx ONLY Models Included FM HUMID R FM HUMID RW FM HUMID RB ...

Page 2: ...original packaging for 24 hours to acclimate to room temperature before use ATTENTION Store the product in a sealed package to avoid environmental damage The operating and storage temperature for the Humidifier should reflect typical environmental conditions of a medical facility environment User Responsibility Service of this device should ONLY be performed by properly trained individuals This pr...

Page 3: ... when filled to the upper line The Amvex Humidifier includes the jar and lid assembly lid sealing gasket and diffuser Technical Specifications Product Dimensions DiaxH 2 6 x 6 25 Jar Capacity To Max Line 115 ml Capacity Of Usable Water 57 5 ml from lower to upper lines Inlet Fitting Oxygen DISS female with wing nut 9 16 18 thread Outlet Fitting Hose barb 1 4 inner diameter plastic tubing Operating...

Page 4: ...vex whether based on agreement neglect or otherwise Amvex reserves the right to stop manufacturing any product or change materials designs or specifications without notice All claims for warranty must first be approved by Amvex s Repair Department 905 764 7736 Toll Free 1 866 462 6839 A valid Return Goods Authorization RGA number must be obtained from Amvex prior to commencement of any warranty cl...

Reviews: