This handbook will discuss the basic sizing used
for our larger
Well-X-Trol
®
s
such as WX-400, 420,
440, and 450 series. This allows you to use the
Well-
X-Trol
®
“principle of separation of air and water” on
larger jobs that are beyond the typical residential
range.
The
Well-X-Trol
®
models we’ll be working with in
this handbook are listed in Table 1.
The design features of these larger models allow
us to apply them more creatively than the smaller
residential models found in the
Well-X-Trol
®
100,
200, and 250 series.
The Larger Well-X-Trol
®
s are Designed and Built
for Maximum Acceptance on Each Operating
Cycle
In the smaller residential
Well-X-Trol
®
s
, the design
is for basic intermittent use and for the usually
found in residential applications. Standard pressure
ranges of (20) PSIG (between pump cut-in and
pump cut-out) are used.
In these applications, full use of the maximum
acceptance volume of the
Well-X-Trol
®
is rarely
required to meet job conditions.
Series 420 & 447
Pressure Switch
Table 1.
WX Model No.
NON-CODE
(NON-AS ME )
WX Model
No.
COD E
(ASM E)
Total
Volume
(Gallons)
Maximum
Acce ptance
Volume
(Gallons)
Maximum
Acce ptance
Factor
(MAF )
WX-401
WX-401-C
17.5
11.25
.65
WX–402
WX–402-C
25
11.25
.45
WX-403
WX-403-C
34
11.25
.33
WX-404
WX-404-C
68
34
.50
WX-405
WX-405-C
90
34
.39
WX-406
WX-406-C
110
34
.31
WX-407
WX-407-C
132
46
.35
WX-421
Not available
158
103
.65
WX-422
Not available
211
137
.65
WX-423
Not available
264
172
.65
WX-424
Not available
317
206
.65
WX-426
Not available
422
274
.65
WX-427
Not available
528
343
.65
WX-447
WX-447-C
53
34
.65
WX-448
WX-448-C
80
52
.65
WX-449
WX-449-C
106
69
.65
WX-450
WX-450-C
132
86
.65
WX-451
WX-451-C
158
102
.65
WX-452
WX-452-C
211
136
.65
WX-453
WX-453-C
264
170
.65
WX-454
WX-454-C
317
205
.65
WX-455
WX-455-C
370
239
.65
WX-456
WX-456-C
422
273
.65
WX-457
WX-457-C
528
341
.65
Based on 30 PS IG p re-charge (P
1
)
1400 Division Road, West Warwick, RI 02893 T: 401.884.6300 F: 401.885.2567 www.amtrol.com
SIZING INSTRUCTIONS
WELL-X-TROL
®
POTABLE WATER WELL TANK
Summary of Contents for WELL-X-TROL WX-401
Page 6: ...6 NOTES...
Page 7: ...7 NOTES...