5470-250-00  

9/2016 

 

Specifications Information and Repair Parts Manual

 

 

 

 

 

  

5470 thru 5497 and 5530 thru 553B

 

 

 

x

 

 

Stamped Stainless Steel Centrifugal Pumps 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

INSTALLATION OF NEW SEAL 

 

The precision lapped faces of mechanical seal are easily damaged. To 
prevent  leaks,  handle  replacement  seal  carefully.  Do  not  touch  seal 
mating faces. 

1. 

Clean  seal  cavity  area  of  casing  cover  (Ref.  5).  Lubricate 
rubber  portion  of  seal  seat  (Ref.  No.  6  without  spring)  with 
soapy  water.  Protect  seal  face  with  cardboard  and  press 
squarely  into  place,  with  polished  side  up.  Then  lay  casing 
cover  onto  adapter  (Ref.  No.  2),  and  center  it  around  motor 
shaft. 

IMPORTANT:

 To avoid rubbing during operation, maintain gap between 

seal and motor shaft until assembly is complete. 
2. 

(High 

volume

  models  only)  Clean  outside  of  shaft  stem  on 

impeller  (Ref.  No.  7).  Lubricate  inside  rubber  portion  of  seal 
head  (Ref.  No.  6  with  spring)  with  soapy  water.  Gently  slide 
seal  onto  impeller  with  polished  side  facing  away  from 
impeller. 

3. 

(High 

head

  models  only)  Clean  outside  of  shaft.  Lubricate 

inside rubber portion of seal head (Ref. No. 6 with spring) with 
soapy  water.  Gently  slide  seal  onto  impeller  with  polished 
side  facing  towards  motor.  Be  careful  not  to  damage  seal 
face. 

NOTE:

  (High 

head

  model  only)  Impeller  is  designed  to  use  no  spring 

retainer between impeller and spring. If replacement seal is equipped 
with spring retainer, discard retainer. 
4. 

Carefully  screw  impeller  back  onto  motor  shaft  by  turning 
clockwise.  Be  sure  to  snug-up  impeller  by  holding  motor 
shaft  as  during  disassembly.  Add  impeller  nut  (Ref.  No.  8), 
then impeller nut (Ref. No. 9) and tighten. 

5. 

Carefully lay casing seal (Ref. No. 10) into desired position. 

NOTE:

  Casing  may  be  rotated  to  position  discharge  port  at  various 

angles. 
6. 

Use  fasteners  and  washers  (Ref.  Nos.  12  &  13)  to  attach 
casing. 

IMPORTANT:

 To avoid leaks, be sure to tighten fasteners in stages to 

prevent casing seal from slipping and becoming pinched. 
7. 

When  assembly  is  complete,  check  for

 

interference  by 

spinning motor shaft by hand and listening. If rubbing heard, 
loosen  fasteners  and  adjust  casing  cover  until  rubbing  is 
gone  (casing  may  also  require  adjustment  on  high  head 
models). If rubbing still persists, remove casing. Then check 
to  be  sure  impeller  is  completely tightened  and  not  binding 
on shaft threads.   

 

Seal  will  produce  minor  drag  when  spinning  motor  shaft,  but  rubbing 
anywhere  else  must  be  eliminated!  Otherwise,  damage  to  pump 
and/or motor may occur.  

For Repair Parts contact dealer where pump was purchased. 

Please provide following information: 

-Model Number 
-Serial Number (if any) 
Part description and number as shown in parts list 

Figure 1 

– Repair Parts Illustration 