AMT 3100-99 Specifications Information And Repair Parts Manual Download Page 3

 
Specifications Information and Repair Parts Manual

 

 

 

 

              

                                                          

3100-99 

 

 

3100-254-00 

07/2012 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
DISASSEMBLY OF BEARING HOUSING: 

 

1. 

Remove  front  pump  assembly  as  described 
under 

TO 

REMOVE 

CUTWATER 

WEARPLATE. 

2. 

Unscrew  impeller,  right  hand  thread  (Ref.  No. 
17). 

3. 

Remove  shaft  sleeve  (Ref.  No.  23)  with  seal 
head (Ref. No. 22) on it. 

4. 

Disassemble bearing housing (Ref. No. 26) from 
pump  adapter  (Ref.  No.  32)  by  removing  four 
hex  head  cap  screws  (Ref.  No.  27)  and  hex 
head locknuts (Ref. No. 25). 

5. 

Remove  shaft  bearing  (Ref.  No.  28)  and  shaft 
(Ref.  No.  29)  as  an  assembly  by  first  removing 
snap  ring  (Ref.  No.  30).  Push  shaft  bearing 
assembly  out  of  bearing  housing  by  rapping  on 
threaded  end  of  shaft  with  a  rawhide  mallet,  or 
block of wood and a hammer. 

6. 

Ball bearings (Ref. No. 28) can now be removed 
from shaft (Ref. No. 29). 

 
ASSEMBLY OF BEARING HOUSING: 
 

1. 

If shaft bearings have been removed from shaft, 
replace  by  sliding  bearing  on  shaft  to  shoulder. 
Replace  shaft  bearing  assembly  by  sliding 
assembly  into  housing  threaded  end  first.  Push 
shaft  bearing  assembly  completely  in  by  gently 
tapping  on  keyway  end  of  shaft  with  a  rawhide 
mallet. Replace snap ring. 

2. 

Reverse steps 1, 2, 3 and 4 (described above) to 
reassemble pump. 
 

NOTE: 

After pump is assembled, it is necessary to rotate 

pump  shaft  by  hand  to  check  for  striking  of  impeller.  If 
striking  or  rubbing  occurs,  adjust  impeller  shims  as 
required (See Shim Adjustment). 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
SHIM ADJUSTMENT 

 

1. 

When  installing  a  replacement  impeller,  it 
may  be  necessary  to  vary  number  of  shims 
(Ref.  No.  21)  that  will  be  required.  This  is 
done  by  adding  one  shim  more  than  was 
removed  and  reassembling  pump  as 
described. 

2. 

Be  sure  that  the  casing  is  snugly  in  place 
and  check  shaft  to  make  sure  it  is  turning 
freely. If it turns freely, check to ensure that 
adapter  (Ref.  No.  32)  and  casing  (Ref.  No. 
7) are fitted metal to metal where they meet 
on  outside.  If  they  are  not  metal  to  metal 
tighten  cap  screws  (Ref.  No.  31)  and 
recheck  shaft  for  free  turning.  Tighten 
carefully,  turning  shaft  while  tightening.  If 
shaft seizes before cap screws (Ref. No. 31) 
are completely tight, disassembly pump and 
remove one shim and repeat reassembly. 

3. 

If  at  any  time  during  above  operation  shaft 
does not turn free or a metal to metal strike 
can  be  heard  or  felt  when  turning  shaft, 
follow procedure indicated above and repeat 
procedure. 

4. 

Above procedure ensures that the pump will 
have  proper  running  clearance  between 
impeller  and  casing  and  perform  like  a  new 
unit with new impeller or motor. 

 

 

 

 

 

Reviews: